4

<To Stop Operation>

Press the ON/OFF button 

1

 again.

Note:
Even if you press the ON/OFF button immediately after shutting down the op-
eration is progress, the air conditioner will not start for about three minutes.
This is to prevent the internal components from being damaged.

3.3. Mode select

Press the operation mode (

) button 

2

 and select the opera-

tion mode 

2

.

Cooling mode

Drying mode

Fan mode

Heating mode

Automatic (cooling/heating) mode

3. Operation

CLOCK

CHECK

RESET

SET

TEST RUN

MODE

FAN

VANE

LOUVER

min

h

AUTO START

AUTO STOP

ON/OFF

TEMP

1

2

5

6

3

3

5

6

2

3.1. Description of “AUTO RESTART FUNCTION”

• This unit is equipped with the auto restart function. When the main

power is turned on, the air conditioner will start operation automati-
cally in the same mode as set with the remote controller before the
shutoff of main power.

• If the unit was set to off with the remote controller before the shutoff of

main power, it will remain stopped even after the main power is turned
on.

• If the unit was in the TEST RUN before the shutoff of main power, it

will start operation, at main power on, in the same mode as set with
the remote controller before the TEST RUN.

Because the room temperature is automatically adjusted in order to
maintain a fixed effective temperature, cooling operation is performed a
few degrees warmer and heating operation is performed a few degrees
cooler than the set room temperature once the temperature is reached
(automatic energy-saving operation).

Mode
Temperature setting
Fan speed

Airflow up/down

Remote Controller settings
Last operation mode
Last set temperature
Last set fan speed

COOL or DRY

Mode HEAT

FAN

3.2. Turning ON/OFF

<To Start Operation>

Press the ON/OFF button 

1

.

Note:

When the unit is restarted, initial settings are as follows.

s

Cooling mode

15 minutes (switches
from heating to cooling)

Set tempe2

°

C

Set temperature

Set temperature -2

°

C

15 minutes (switches
from cooling to heating )

Information for multi system air conditioner (Outdoor
unit: MXZ series)

s

s

s

s

s

Multi system air conditioner (Outdoor unit: MXZ series) can con-
nect two or more indoor units with one outdoor unit. According to
the capacity, two or more units can operate simultaneously.

• When you try to operate two or more indoor units with one outdoor unit

simultaneously, one for the cooling and the other for heating, the opera-
tion mode of the indoor unit that operates earlier is selected. The other
indoor units that will start the operation later cannot operate, indicating
an operation state in flashing.
In this case, please set all the indoor units to the same operation mode.

• There might be a case that the indoor unit, which is operating in 

(AUTO) mode. Cannot change over to the operating mode (COOL 

HEAT) and becomes a state of standby.

• When indoor unit starts the operation while the defrosting of outdoor

unit is being done, it takes a few minutes (max. about 15 minutes) to
blow out the warm air.

• In the heating operation, though indoor unit that does not operate may

get warm or the sound of refrigerant flowing may be heard, they are not
malfunction. The reason is that the refrigerant continuously flows into it.

Automatic operation

According to a set temperature, cooling operation starts if the room tem-
perature is too hot and heating operation starts if the room temperature
is too cold.

During automatic operation, if the room temperature changes and re-
mains 2 

°

C or more above the set temperature for 15 minutes, the air

conditioner switches to cooling mode. In the same way, if the room tem-
perature remains 2 

°

C or more below the set temperature for 15 min-

utes, the air conditioner switches to heating mode.

3.4. Temperature setting

s

s

s

s

s

To decrease the room temperature:

Press 

 button 

3

 to set the desired temperature.

The selected temperature is displayed 

3

.

s

s

s

s

s

To increase the room temperature:

Press 

 button 

3

 to set the desired temperature.

The selected temperature is displayed 

3

.

• Available temperature ranges are as follows:

Cooling/Drying:

19 - 30 

°

C

Heating:

17 - 28 

°

C

Automatic:

19 - 28 

°

C

• The display flashes either 8 

°

C - 39 

°

C to inform you if the room tem-

perature is lower or higher than the displayed temperature.

KB79H174H04_EN.pm6

08.6.23, 2:46 PM

4

Summary of Contents for SEZ-KD25

Page 1: ...I FUNZIONAMENTO Leggere attentamente questi istruzioni di funzionamento prima di avviare l unità per un uso corretto e sicuro della stessa DRIFTSMANUAL Läs denna driftsmanual noga för säkert och korrekt bruk innan luftkonditioneringen används DRIFTSMANUAL Læs venligst denne driftsmanual grundigt før airconditionanlægget betjenes af hensyn til sikker og korrekt brug MANUAL DE OPERAÇÃO Para seguranç...

Page 2: ...cleaning indication Symbols used in the text Warning Describes precautions that should be observed to prevent danger of injury or death to the user Caution Describes precautions that should be observed to prevent damage to the unit Symbols used in the illustrations Indicates a part which must be grounded Warning The unit must not be installed by the user Ask the dealer or an authorized company to ...

Page 3: ... high humidity To avoid misplacing the remote controller install the holder included with the remote con troller on a wall and be sure to always place the remote controller in the holder after use Battery installation replacement 1 Remove the top cover insert two AAA batter ies and then install the top cover Top cover 2 Press the Reset button CLOCK CHECK RESET SET TESTRUN MODE FAN VANE LOUVER min ...

Page 4: ...ioner Outdoor unit MXZ series s s s s sMulti system air conditioner Outdoor unit MXZ series can con nect two or more indoor units with one outdoor unit According to the capacity two or more units can operate simultaneously When you try to operate two or more indoor units with one outdoor unit simultaneously one for the cooling and the other for heating the opera tion mode of the indoor unit that o...

Page 5: ...at ing 2 Emergency operation In cases where the remote control unit does not operate properly use either the COOL or HEAT button on the wireless remote control signal receiver to toggle the unit on or off On cooler only units pushing the HEAT button toggles the fan on and off Pressing the COOL or HEAT button selects the following settings Operation mode COOL HEAT Preset temperature 24 C 75 F 24 C ...

Page 6: ...button is pressed Air conditioner operates without the ON OFF button being pressed Here is the solution Unit is operating normally Clean the filter Airflow is reduced when the filter is dirty or clogged Check the temperature adjustment and adjust the set temperature Make sure that there is plenty of space around the outdoor unit Is the indoor unit air intake or outlet blocked Has a door or window ...

Page 7: ...on has operated to protect the air conditioner Do not attempt to repair this equipment by yourself Turn off the power switch immediately and consult your dealer Be sure to provide the dealer with the model name High sound absorbing rooms Broadcasting studio music room etc 3 to 7 dB Normal rooms Reception room hotel lobby etc 6 to 10 dB Low sound absorbing rooms Office hotel room 9 to 13 dB Locatio...

Page 8: ...is provided to avoid misplacing the remote controller Install the remote controller in a location that meets the following conditions Out of the direct sun light Away from any heat sources Out of the airflow from the air conditioner cool or warm Where the operation of the remote controller can easily be performed and the display is readily visible to the user Out of the reach of small children NOT...

Page 9: ... should be installed by licensed electric contractor accordingly to local code requirement SEZ KD35VAL 0 05 0 46 7 9 11 5 15 35 50 23 28 33 200 990 700 21 SEZ KD71VAL 0 10 0 84 12 16 20 5 15 35 50 30 35 40 200 1190 700 27 Model Power supply Input Indoor only kW Current Indoor only A Airflow Lo Mid Hi CMM Ext static pressure Pa Noise level Lo Mid Hi dB Dimension H W D mm Weight kg SEZ KD50VAL 0 07 ...

Page 10: ...e 2006 95 EC Electromagnetic Compatibility Directive 89 336 EEC 2004 108 EC This product is designed and intended for use in the residential commercial and light industrial environment HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN KB79H174H04 The product at hand is based on the following EU regulations ...

Reviews: