5-143
Resetting the origin
5 Maintenance and Inspection
5.6.1 Setting the origin with the origin data input method
(1) Confirming the origin data
The origin data to be input is noted in the origin data sheet. (See
Fig.5-28 : Origin data label (an example)
The origin data history table is attached on the back of the following covers.
Page 101, "5.3.2 Installing/removing the cover"
, remove the cover above and confirm the value.
The value given in the default setting column is the origin settings set with the jig method before shipment.
* The origin data to input is found on also the robot examination report sheet.
Always install/remove the cover with the controller control power turned OFF.
Failure to do so could lead to physical damage or personal injury should the robot
start moving due to incorrect operations.
Model
Cover
RH-3FRH/6FRH/12FRH/20FRH series
Battery cover
RH-3FRHR series
Base cover B (L)
● Origin data history table (Origin Data History) Serial No.ES804008
(O: O(Alphabet), 0: Zero)
Date
Default
. . .
. . .
. . .
D
V!#S29
J1
06DTYY
J2
2?HL9X
J3
1CP55V
J4
T6!M$Y
J5
J6
Method
J
J ・ A ・ U
J ・ A ・ U
J ・ A ・ U
Note) Meanings of symbols in
method column
J: Jig method
A: ABS origin method
U: User origin method
WARNING