12 DATA USED FOR POSITIONING CONTROL
12.7 Monitor Data
501
12
[Md.123] Torque during command
• This area stores the command torque during torque control mode. (Buffer memory
0.1)%
• This area stores the command torque during continuous operation to torque control mode.
• "0" is stored other than during torque control mode or continuous operation to torque control mode.
Refresh cycle: Operation cycle (Torque control mode and continuous operation to torque control mode only)
■
Reading the monitor value
Refer to "[Md.122] Speed during command".
Page 500 [Md.122] Speed during command
• Buffer memory address
Refer to the following for the buffer memory address in this area.
[Md.124] Control mode switching status
• This area stores the switching status of control mode.
Refresh cycle: Operation cycle
■
Reading the monitor value
• Monitoring is carried out with a decimal display.
• Buffer memory address
Refer to the following for the buffer memory address in this area.
[Md.125] Servo status3
• This area stores the servo status3.
• Continuous operation to torque control mode: Turn ON when the continuous operation to torque control mode.
Refresh cycle: Operation cycle
■
Reading the monitor value
• Monitoring is carried out with a hexadecimal display.
• Buffer memory address
Refer to the following for the buffer memory address in this area.
Control mode switching status
0: Not during control mode switching
Monitor
value
1: Position control mode - continuous operation
to torque control mode, speed control mode -
continuous operation to torque control mode
switching
2: Waiting for the completion of control mode
switching condition
b15
b12
b8
b4
b0
Stored items
Meaning
0: OFF
1: ON
b14
Continuous operation to
torque control mode
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......