494
12 DATA USED FOR POSITIONING CONTROL
12.7 Monitor Data
[Md.102] Deviation counter value
• This area stores the pulse droop.
(Buffer memory details) pulse
Refresh cycle: Operation cycle
■
Reading the monitor value
Refer to the following.
Page 492 [Md.62] Amount of the manual pulser driving carrying over movement
• Buffer memory address
Refer to the following for the buffer memory address in this area.
[Md.103] Motor rotation speed
• This area stores the motor speed updated in real time.
(Buffer memory
0.01) r/min
*1
*1
The unit is mm/s at linear servo use.
Refresh cycle: Operation cycle
■
Reading the monitor value
Refer to the following.
Page 492 [Md.62] Amount of the manual pulser driving carrying over movement
• Buffer memory address
Refer to the following for the buffer memory address in this area.
[Md.104] Motor current value
• This area stores the present motor current value of the motor.
(Buffer memory
0.1)%
Refresh cycle: Operation cycle
■
Reading the monitor value
• Monitoring is carried out with a decimal display.
• Buffer memory address
Refer to the following for the buffer memory address in this area.
-1
Unit conversion table ([Md.104])
R
Unit conversion
[Md.104] Motor current value
R
×
10
m
m
%
Unit
Decimal integer
value
Monitor
value
Actual
value
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......