12 DATA USED FOR POSITIONING CONTROL
12.3 Basic Setting
425
12
Detailed parameters2
n: Axis No. - 1
Item
Setting value, setting range
Default value
Buffer memory
address
Value set with the engineering tool
Value set with a program
[Pr.25]
Acceleration time 1
1 to 8388608 (ms)
1 to 8388608 (ms)
1000
36+150n
37+150n
[Pr.26]
Acceleration time 2
38+150n
39+150n
[Pr.27]
Acceleration time 3
40+150n
41+150n
[Pr.28]
Deceleration time 1
42+150n
43+150n
[Pr.29]
Deceleration time 2
44+150n
45+150n
[Pr.30]
Deceleration time 3
46+150n
47+150n
[Pr.31]
JOG speed limit value
The setting range differs depending on the "[Pr.1] Unit setting".
20000
48+150n
49+150n
[Pr.32]
JOG operation acceleration
time selection
0: [Pr.9] Acceleration time 0
0
0
50+150n
1: [Pr.25] Acceleration time 1
1
2: [Pr.26] Acceleration time 2
2
3: [Pr.27] Acceleration time 3
3
[Pr.33]
JOG operation deceleration
time selection
0: [Pr.10] Deceleration time 0
0
0
51+150n
1: [Pr.28] Deceleration time 1
1
2: [Pr.29] Deceleration time 2
2
3: [Pr.30] Deceleration time 3
3
[Pr.34]
Acceleration/deceleration
process selection
0: Trapezoid
acceleration/deceleration
process
0
0
52+150n
1: S-curve
acceleration/deceleration
process
1
[Pr.35]
S-curve ratio
1 to 100 (%)
1 to 100 (%)
100
53+150n
[Pr.36]
Sudden stop deceleration
time
1 to 8388608 (ms)
1 to 8388608 (ms)
1000
54+150n
55+150n
[Pr.37]
Stop group 1 sudden stop
selection
0: Normal deceleration stop
0
0
56+150n
1: Sudden
stop
1
[Pr.38]
Stop group 2 sudden stop
selection
0: Normal deceleration stop
0
57+150n
1: Sudden
stop
1
[Pr.39]
Stop group 3 sudden stop
selection
0: Normal deceleration stop
0
58+150n
1: Sudden
stop
1
[Pr.40]
Positioning complete signal
output time
0 to 65535 (ms)
0 to 65535 (ms)
0 to 32767: Set as a decimal
32768 to 65535: Convert into
hexadecimal and set
300
59+150n
[Pr.41]
Allowable circular
interpolation error width
The setting value range differs depending on the "[Pr.1] Unit setting".
100
60+150n
61+150n
[Pr.42]
External command function
selection
0: External
positioning
start
0
0
62+150n
1: External speed change request
1
2: Speed-position,
position-speed
switching request
2
3: Skip
request
3
4: High speed input request
4
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...