[Pr.96] Operation cycle setting
Set the operation cycle.
The default value is "FFFFH: Automatic setting".
*1
Available only when "1: SSCNET
/H" is set in "[Pr.97] SSCNET setting". If "0: SSCNET
" is set, the error "Operation cycle setting
error" (error code: 1B73H) occurs.
• In this parameter, the value set in flash ROM of Simple Motion module is valid at power supply ON or CPU
module reset. Fetch by PLC READY signal OFF to ON is not executed. Execute flash ROM writing to
change after setting a value to buffer memory. Confirm the current operation cycle in "[Md.132] Operation
cycle setting".
• When "FFFFH: Automatic setting" is set, the optimum operation cycle is set according to "[Pr.152] Maximum
number of control axes". Confirm the set operation cycle in "[Md.132] Operation cycle setting".
*1
• Confirm that "[Md.133] Operation cycle over flag" does not turn ON. If the flag is ON, the operation cycle
over has been generated. Correct the positioning content or increase the operation cycle.
*1
"[Md.133] Operation cycle over flag" may turn ON depending on the positioning content.
[Pr.97] SSCNET setting
Set the servo network.
The connectable servo amplifier differs by this parameter. When unconnectable connected device is set in "[Pr.100]
Connected device", the warning "Incompatible device" (warning code: 0C81H) occurs at the power supply ON or PLC READY
ON.
In this parameter, the value set in flash ROM of Simple Motion module is valid at power supply ON or CPU
module reset. Fetch by PLC READY signal OFF to ON is not executed. Execute flash ROM writing to change
after setting a value to buffer memory.
Operation cycle setting
Setting value
0.888 ms
0000H
1.777 ms
0001H
3.555 ms
0002H
0.444 ms
0200H
Automatic setting
FFFFH
SSCNET setting
Setting value
SSCNET
0
SSCNET
/H
1
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......