background image

QnA Series CPU Direct Driver    

GP-Pro EX Device/PLC Connection Manual

8

3.2

Setting Example 2

„

Setting of GP-Pro EX

‹

Communication Settings

To display the setting screen, select [Device/PLC Settings] from [System setting window] in workspace. 

„

Device Setting

There is no setting on the External Device. The speed automatically switches according to the Display setting.

Summary of Contents for QnA Series

Page 1: ... QnA Series CPU Direct Driver 1 System Configuration 3 2 Selection of External Device 6 3 Example of Communication Setting 7 4 Setup Items 9 5 Cable Diagram 13 6 Supported Device 17 7 Device Code and Address Code 19 8 Error Messages 21 ...

Page 2: ...Device Select a model series of the External Device to be connected and connection method 2 Selection of External Device page 6 3 Example of Communication Settings This section shows setting examples for communicating between the Display and the External Device 3 Example of Communication Setting page 7 4 Setup Items This section describes communication setup items on the display Set communication ...

Page 3: ...LSEC QnA Series Q4A CPU Q3A CPU Q2A CPU S1 Q2A CPU Q2ASH CPU S1 Q2ASH CPU Q2AS CPU S1 Q2AS CPU Q4AR CPU CPU Direct RS232C Setting Example 1 page 7 Cable Diagram 1 page 13 RS422 485 4wire Setting Example 2 page 8 Cable Diagram 2 page 14 2 port adapter II by Pro face 1 Model GP070 MD11 1 Supported by 2 port adapter II Rev B or later 2 port adapter II does not support the communication in 38 400 Plea...

Page 4: ...OM1 1 COM2 1 COM3 2 COM4 2 Set up the SIO type with the DIP switch Please set up as follows according to SIO type to be used COM3 2 COM3 2 PS 3711A COM1 1 COM2 2 COM2 2 COM2 2 PL 3000B PL 3600T PL 3600K PL 3700T PL 3700K PL 3900T COM1 1 2 COM2 1 COM3 COM4 COM1 1 2 COM1 1 2 DIP switch Setting Description 1 OFF 1 1 When using PS 3450A PS 3451A PS3000 BA and PS3001 BD turn ON the set value Reserved a...

Page 5: ...ion to RD RXD None 7 OFF Short circuit of SDA TXA and RDA RXA Not available 8 OFF Short circuit of SDB TXB and RDB RXB Not available 9 OFF RS RTS Auto control mode Disabled 10 OFF DIP switch Setting Description 1 OFF Reserved always OFF 2 ON SIO type RS 422 485 3 ON 4 OFF Output mode of SD TXD data Always output 5 OFF Terminal resistance 220Ω insertion to SD TXD None 6 OFF Terminal resistance 220Ω...

Page 6: ...tem Configuration page 3 Use System Area Check this option when you synchronize the system data area of Display and the device memory of External Device When synchronized you can use the ladder program of External Device to switch the display or display the window on the display Cf GP Pro EX Reference Manual Appendix 1 4 LS Area Direct Access Method This can be also set with GP Pro EX or in off li...

Page 7: ...and the External Device recommended by Pro face are shown 3 1 Setting Example 1 Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Settings of External Device There is no setting on the External Device The speed automatically switches according to the Display setting ...

Page 8: ...ting Example 2 Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Device Setting There is no setting on the External Device The speed automatically switches according to the Display setting ...

Page 9: ...Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Setup Items Setup Description SIO Type Select the SIO type to communicate with the External Device Speed Select speed between the External Device and the Display Data Length Select data length Parity Select how to check parity Stop Bit Select stop bit length Flow Control S...

Page 10: ...nteger from 0 to 255 to enter how many times the Display retransmits the command Wait To Send Use an integer from 0 to 255 to enter standby time ms for the Display from receiving packets to transmitting next commands RI VCC You can switch RI VCC of the 9th pin when you select RS232C for SIO type It is necessary to change RI 5V by changeover switch of IPC when connect with IPC Please refer to the m...

Page 11: ...e Select the SIO type to communicate with the External Device To make the communication settings correctly confirm the serial interface specifications of Display unit for SIO Type We cannot guarantee the operation if a communication type that the serial interface does not support is specified For details concerning the serial interface specifications refer to the manual for Display unit Speed Sele...

Page 12: ... 0 to 255 to enter how many times the Display retransmits the command Wait to Send ms Use an integer from 0 to 255 to enter standby time ms for the Display from receiving packets to transmitting next commands Setup Items Setup Description RI VCC You can switch RI VCC of the 9th pin when you select RS232C for SIO type It is necessary to change RI 5V by changeover switch of IPC when connect with IPC...

Page 13: ... of the External Device for more details SG and FG are connected inside the Display When connecting SG to the External Device design the system not to form short circuit loop Connect the isolation unit when communication is not stabilized under the influence of a noise etc Cable Diagram 1 Display Connection Port Cable Notes GP COM1 ST COM1 IPC 1 PC AT 1 Only the COM port which can communicate by R...

Page 14: ...e COM port which can communicate by RS 422 485 4 wire can be used IPC COM Port page 4 A Mitsubishi A connection cable by Pro face CA3 CBLA 01 5m B Your own cable The cable length must be 500m or less External Device CA3 CBLA 01 Display Display Termination resistance 330Ω 1 4W Termination resistance 330Ω 1 4W D sub 9 pin socket Pin Signal name 1 2 3 7 4 9 8 6 5 Shell RDA RDB SDA SDB ERA ERB CSA CSB...

Page 15: ...by Pro face CA3 ADPCOM 01 2 port adapter cable for AGP by Pro face CA3 MDCB11 5m 2 port adapter II by Pro face GP070 MD11 B Your own cable 2 port adapter II by Pro face GP070 MD11 The cable length must be 600m or less GP 4 COM2 4 All GP models except GP 3200 series and AGP 3302B C Online adapter by Pro face CA4 ADPONL 01 2 port adapter cable for AGP by Pro face CA3 MDCB11 5m 2 port adapter II by P...

Page 16: ... sub 9 pin socket Signal name RDA RDB SDA SDB SG CSB ERB CSA ERA FG Signal name SDA SDB RDA RDB SG Terminal block GP070 MD11 External Device Shield 1 2 3 7 5 6 9 8 4 Shell Pin Your own cable Termination resistance 330Ω 1 4W Display CA3 MDCB11 D sub 9 pin plug Signal name RDA RDB SDA SDB SG Signal name SDA SDB RDA RDB SG Terminal block GP070 MD11 External Device CA4 ADPONL 01 Display D sub 9 pin pl...

Page 17: ...52 Annunciator F00000 F32767 F00000 F32752 Edge Relay V00000 V32767 V00000 V32752 Step Relay S0000 S8191 S0000 S8176 Link Relay B0000 B7FFF B0000 B7FF0 Special Link Relay SB000 SB7FF SB000 SB7F0 Timer Contact TS00000 TS23087 Timer Coil TC00000 TC23087 Retentive Timer Contact SS00000 SS23087 Retentive Timer Coil SC00000 SC23087 Counter Contact CS00000 CS23087 Counter Coil CC00000 CC23087 Timer Curr...

Page 18: ...his is the device name for conversion with GP Pro PB III for Windows When you newly specify the device we recommend that you should use the file register Block switching is not necessary Please refer to the GP Pro EX Reference Manual for system data area Cf GP Pro EX Reference Manual Appendix 1 4 LS Area Direct Access Method Please refer to the precautions on manual notation for icons in the table...

Page 19: ... address divided by 16 Annunciator F 0085 Value of word address divided by 16 Edge Relay V 0086 Value of word address divided by 16 Step Relay S 0087 Value of word address divided by 16 Link Relay B 0088 Value of word address divided by 0x10 Special Link Relay SB 0089 Value of word address divided by 0x10 Timer Current Value TN 0060 Word Address Retentive Timer Current Value SN 0062 Word Address C...

Page 20: ...ction Manual 20 File Register 0R 31R 0R 0010 Word Address 1R 0011 Word Address 2R 0012 Word Address 3R 0013 Word Address 28R 002C Word Address 29R 002D Word Address 30R 002E Word Address 31R 002F Word Address Device Device Name Device Code HEX Address Code ...

Page 21: ... External Device set with GP Pro EX Initial value PLC1 Error Message Displays messages related to the error which occurs Error Occurrence Area Displays IP address or device address of External Device where error occurs or error codes received from External Device IP address is displayed such as IP address Decimal MAC address Hex Device address is diplayed such as Address Device address Received er...

Page 22: ...QnA Series CPU Direct Driver GP Pro EX Device PLC Connection Manual 22 ...

Reviews: