41
OCH681
(2) Function of connector
*
2
“Power failure automatic recovery” can be set by either remote controller or this DIP SW. If one of them is set to ON,
“Auto recovery” activates. Please set “Auto recovery” basically by remote controller because all units do not have DIP SW.
Please refer to the indoor unit installation manual.
*
3
Please do not use SW7-3, 4 ,6 usually. Trouble might be caused by the usage condition.
Types
Connector
Function
Action by open/short operation
Effective timing
Short
Open
Connector
CN31
Emergency operation
Start
Normal
When power supply ON
The black square (
■
) indicates a switch position.
Type of
Switch
Switch
No.
Function
Action by the switch operation
Effective timing
ON
OFF
DIP
switch
SW5
1
No function
—
—
—
2
Power failure
automatic recovery*
2
Auto recovery
No auto recovery
When power supply ON
3,4,5,6
No function
—
—
—
SW7*
3
1,2,3
No function
—
—
—
4
No function
—
—
—
5
No function
—
—
—
6
Defrost setting
For high humidity
Normal
Always
SW9
1
No function
—
—
—
2
No function
—
—
—
3,4
No function
—
—
SW6
1
Model select
2
3
4
5
6
7
8
PUHZ-W85/112VAA
8
1 2 3 4 5 6 7
OFF
ON
85V
MODEL
SW6
8
1 2 3 4 5 6 7
OFF
ON
112V
MODEL
SW6
PUHZ-W85/112YAA
8
1 2 3 4 5 6 7
OFF
ON
85Y
MODEL
SW6
8
1 2 3 4 5 6 7
OFF
ON
112Y
MODEL
SW6