5
O
U
T
L
IN
ES
A
N
D
D
IMEN
SI
O
N
S
PU
H
Z
-SH
W
80
V
A
A
.U
K
PU
H
Z
-SH
W
11
2V
A
A
.U
K
PU
H
Z
-SH
W
80
YA
A
.U
K
PU
H
Z
-SH
W
11
2Y
A
A
.U
K
PU
H
Z
-SH
W
80
V
A
A
-B
S.
U
K
PU
H
Z
-SH
W
11
2V
A
A
-B
S.
U
K
PU
H
Z
-SH
W
80
YA
A
-B
S.
U
K
PU
H
Z
-SH
W
11
2Y
A
A
-B
S.
U
K
PU
H
Z
-SW
75
V
A
A
.U
K
PU
H
Z
-SW
10
0V
A
A
.U
K
PU
H
Z
-SW
75
YA
A
.U
K
PU
H
Z
-SW
10
0Y
A
A
.U
K
PU
H
Z
-SW
75
V
A
A
-B
S.
U
K
PU
H
Z
-SW
10
0V
A
A
-B
S.
U
K
PU
H
Z
-SW
75
YA
A
-B
S.
U
K
PU
H
Z
-SW
10
0Y
A
A
-B
S.
U
K
U
n
it:
m
m
FRONT PIPING COVER
REAR PIPING COVER
HANDLE FOR MOVING
HANDLE FOR MOVING
AIR INTAKE
REAR AIR INTAKE
HANDLE FOR MOVING
HANDLE FOR MOVING
SIDE AIR INTAKE
DRAIN HOLE(5X
{
33)
BOTTOM PIPING HOLE
(KNOCK OUT)
1
2
0
2
0
0
11
6
43
276
88
188
9
5
134
INSTALLATION FEET
2XU SHAPED NOTCH HOLES
(FOUNDATION BOLT M10)
2X12X36 OVAL HOLES
(FOUNDATION BOLT M10)
SIDE AIR INTAKE
AIR DISCHARGE
REAR AIR INTAKE
(1
9
)
5
2
0
4
8
0
600
225
75
69
59
2
8
5
6
7
2
5
3
5
6
7
FRONT TRUNKING HOLE
(KNOCK-OUT)
POWER SUPPLY WIRING HOLE
(2X
{
27 KNOCK-OUT)
FRONT PIPING HOLE
(KNOCK-OUT)
55
62
5
8
7
1
4
6
2
5
3
0
92
90
{
92
RIGHT PIPING HOLE
(KNOCK-OUT)
RIGHT TRUNKING HOLE
(KNOCK-OUT)
POWER SUPPLY WIRING HOLE
(2X
{
27 KNOCK-OUT)
55
92
44
40
118
5
8
3
0
9
2
2
5
7
1
{
92
POWER SUPPLY WIRING HOLE
(2X
{
27 KNOCK-OUT)
REAR TRUNKING HOLE
(KNOCK-OUT)
REAR PIPING HOLE
(KNOCK-OUT)
55
38
5
8
7
1
3
0
5
5
2
5
92
65
{
92
SERVICE PANEL
TERMINAL CONNECTION
LEFT
POWER SUPPLY WIRING
RIGHT
INDOOR / OUTDOOR WIRING
EARTH TERMINAL
1
2
*1
3
2
8
*1
3
3
6
*2
8
0
2
3
0
5
2
8
1
0
2
0
363
1050
*2
INDICATION OF TERMINAL CONNECTION LOCATION.
2
1
REFRIGERANT GAS PIPE CONNECTION (FLARE)
{
15.88(5/8F)
EXAMPLE OF NOTES
REFRIGERANT LIQUID PIPE CONNECTION (FLARE)
{
9.52(3/8F)
INDICATION OF STOP VALVE CONNECTION LOCATION.
*1
OVER
50mm
OVER
15mm
OVER 1
000mm
OVER 1
50mm
FR
EE
SERVICE
SPACE
OVER
OVER
OVER
O
VER
O
VER
1
5
0
5
0
0
50
500
15
<FOUNDATION BOLT HEIGHT>
FOUNDATION
L
ESS
T
H
A
N
3
0
THE DIAGRAM BELOW SHOWS A BASIC EXAMPLE.
EXPLANATION OF PARTICULAR DETAILS ARE
GIVEN IN THE INSTALLATION MANUALS etc.
DIMENSIONS OF SPACE NEEDED
FOR SERVICE ACCESS ARE
SHOWN IN THE BELOW DIAGRAM.
PLEASE SECURE THE UNIT FIRMLY
WITH 4 FOUNDATION (M10) BOLTS.
(BOLTS AND WASHERS MUST BE
PURCHASED LOCALLY.)
1 FREE SPACE (AROUND THE UNIT)
2 SERVICE SPACE
3 FOUNDATION BOLTS
4 PIPING-WIRING DIRECTIONS
PIPING AND WIRING CONNECTIONS
CAN BE MADE FROM 4 DIRECTIONS:
FRONT,RIGHT,REAR AND BELOW.
PIPING KNOCK-OUT HOLE DETAILS
O
C
H
6
5
1
PU
H
Z
-SH
W
11
2Y
A
A
.U
K
PU
H
Z
-SH
W
80
YA
A
.U
K
All manuals and user guides at all-guides.com