33
33
OPERATING
PROCEDURE
PHOTOS
5. Removing the front panel
(1) Remove the intake grille.
(2) Remove the 2 screws at the lower part of the
front
panel.
(3) Pull the front panel down to remove.
(4) Disconnect the blue connector of the controller.
6. Removing the louver motor
(1) Remove the intake grille.
(2) Remove the front panel.
(3) Remove the 5 screws of the swing louver and
remove the swing louver.
(4) Remove the 2 screws of the louver motor and
remove the louver motor.
(5) Remove the electrical parts cover.
(6) Disconnect the yellow connector CNL (LOUVER)
on the indoor controller board.
7. Removing the indoor coil thermistor
(1) Remove the intake grille.
(2) Remove the front panel.
(3) Remove the 10 screws of the insulation panel
and remove the insulation panel .
(4) Remove the swing louver.
(5) Remove the screw of the piping cover and
remove the piping cover.
(6) Remove the indoor coil thermistor from the
holder on the copper pipe.
(7) Remove the electrical parts cover.
(8) Disconnect the connector CN21 on the indoor
controller
board.
Photo 5
Photo 6
Photo 7
Photo 8
Photo 9
Swing louver
Controller
Screws
Top panel
Front panel
Swing
louver
screws
Screws
Swing
louver
Swing louver
<Back view of swing louver>
Piping cover
Screw
Screw
Insulation panel
Indoor heat
exchanger
Indoor coil
thermistor
Screws
Screws
Louver motor