Mitsubishi Electric PRC- 8MYA Operation Manual Download Page 2

1

Warning.

Use only optional parts authorized by Mitsubishi Electric.

     

If the accessories are installed improperly, water leakage, electric shock
or fire may result.
Ask your dealer or an authorized company to install them.

Danger and the extent caused when wrong handling is done
are divided by displaying        warning and        attention and
are explained.

Before operating the unit ,make sure you read all the
"Safety precautions".   

"Safety precautions" lists important points about safety.
Please be sure to follow them.   

The display and its meaning are given below.

Warning

Erroneous handling gives a high possibility
to induce serious results such as death
or heavy injury.

Caution

Erroneous handling may induce serious
injury depending on the situation.   

Warning.

Carefully read the labels affixed to the main unit.

1. Safety precautions.

Caution.

    

     

Ask your dealer or specialized subcontractor for

installation.

    

Conducting installation work by yourself improperly may cause
a fire, electric shock or water leakage. 

1.1 Installation.

The Installation Manual details the suggested installation method.   
Any structural alteration necessary for installation must comply with
local building code requirements.
After you have read this manual, keep it and the Installation
Manual in a safe place for easy reference whenever a question arises.
If the unit is going to be operated by another person, make sure
that this manual is given him or her.
The unit should not be installed by the user.
 (Safety and the function cannot be secured.)

Never repair the unit, remodel or transfer it to another

site by yourself.

      

If they are performed improperly, water leakage, electric shock or
fire may result.
If you need to have the unit repaired or moved, consult your dealer.

Take a proper measure to suppress the critical

concentration of refrigerant, if leaked when installing

the unit in a small room.

     

The limit density is made not to be exceeded even if the refrigerant
leaks by any chance.
You are necessary to ventilation measures to prevent the accident.
If the refrigerant leaks, hypoxia accident may caused.
For the countermeasure to be taken, consult your dealer.

The unit should be securely installed.

If the unit is loosely mounted, it may fall, causing injury.

Never install on the place where a combustible gas might
leak.

    

The gas may ignite or explode when the gas leaks and collects
in surroundings of the unit.

Caution.

The unit should be installed in a location where air and
noise emitted by the unit will not disturb the neighbours.

2 )   Drain piping (hose) 

Caution.

    

3 )   Power line, fuse or circuit breaker 

Make sure that there is a main power switch.

4 )   Earth connection 

Remote controller is not allowed to install for the place
where direct sunshine strikes.

Please do not use the unit in the following places.

Place where a lot of oil (The machine oil is contained), moistures,

and dust exist.

Place where a lot of salinity such as beach districts exists.

Place where sulfur gas, volatile gas, and corroded gas are filled.

Place where acid solution is frequently used.

Place where special spray is frequently used.

Hot spring zone.

Near machine (high cycle welding machine etc.) generating high cycle.

Place where ventilation entrance of unit is closed by snowfall.

The main body might corrode when the unit is used in such a place,

the refrigerant leak, the performance of the unit decrease remarkably,

and it cause the damage of parts of the unit.

1 )   Unit 

Warning.

Please pay attention to the refrigerant   (Freon gas).

A non flammable, non-toxic, odourless refrigerant is used for this air
conditioner.

The refrigerant is collected on the floor side in the room because the
specific gravity are larger than air. And, it causes the hypoxia accident.

When the refrigerant gas leaks by any chance, the user must ventilates
air enough by stopping the drive of the unit and opening the door.

Warning.

The unit must be installed on stable, level surface in a 
place where there is no accumulation of snow, leaves or
rubbish.

Do not stand on, or place any item on the unit.

    

You may fall down or the item may fall, causing injury.

The heating of refrigerant is noted.

   

     
When the refrigerant touches the fire etc., it was decomposed and
a poisonous gas is generated.
Do not use the welding machine etc., in the room close up of the
installation of the air conditioner.

Install drain piping (hose) according to
Installation Manual to ensure proper drainage.

    

Improper drain piping (hose) may cause water
leakage and damage to furniture or other possessions.

Use breaker or fuse with proper capacity.

   

Using a wire or copper wire instead of proper capacity can cause fire
or trouble.
Other appliances connected to the same line could cause an overload.

When installing at a watery place, provide an electric
leak breaker.
         

Failure to mount the electric leak breaker may cause electric shock.

The unit must be properly earth connected.

      
Do not connect the earth wire to gas pipe, city water
pipe, lightning rod or telephone earth wire.
Improper earth connection may cause electric shock.

The symbols used here represent that as follows.

Never do this.

Never touch without wearing glove on your hands.

Make sure to connect earth line.

Summary of Contents for PRC- 8MYA

Page 1: ...lease read this manual to operate safety before using 2 Please keep this manual in the place where it is always seen to use this manual with Installation manual after reading 3 The customer must not install and not transfer the unit by themselves Safety and the function cannot be secured Service ref PRC 8MYA 03 PRC 10MYA 03 PRC 12MYA 03 PRC 15MYA 03 PRC 20MYA 03 PRC 24MYA 03 PRC 32MYA 03 Model PRC...

Page 2: ... will not disturb the neighbours 2 Drain piping hose Caution 3 Power line fuse or circuit breaker Make sure that there is a main power switch 4 Earth connection Remote controller is not allowed to install for the place where direct sunshine strikes Please do not use the unit in the following places Place where a lot of oil The machine oil is contained moistures and dust exist Place where a lot of ...

Page 3: ...ther than that designed originally may result in the deterioration of the quality Consult your dealer in this regard Stop the operation and turn the power source switch off for cleaning The fan inside rotating at high speed can cause injury Do not locate vessels filled with water like a flower vase onto the unit Water if flooded may enter into the unit causing electric shock Do not step on or plac...

Page 4: ...hanger PRC 8 PRC 10 PRC 12 PRC 15 PRC 20 PRC 24 PRC 32 Air inlet Air outlet Air inlet Air inlet Wiring hole Drain pipe Control module Service panel Air inlet Air outlet Air inlet Air inlet Drain pipe Service panel Air outlet Air outlet Service panel Wiring hole Control module 4 5 In case of failure 1 Never remodel the air conditioner Consult your dealer for any repair service Improper repair work ...

Page 5: ...ned environments frequent operational failure can be excepted It is advisable to avoid these type of installation sites For further details consult with your dealer 3 Choose a place where cool air and noise from the outdoor air outlet of the air conditioner do not inconvenience the neighbors 4 If any obstruction is placed near the air outlet of the unit decreased performance and increased noise ca...

Page 6: ...e power supply is turned ON before use Keep the power supply turned ON at all times when the air conditioner is in use Use of the unit without power can result in compressor failure Check and confirm the power circuit before use For the contents refer to the previously described chapter Crucial points to be observed for safety Before starting operation 6 1 ON OFF Start operation Press the ON OFF b...

Page 7: ...se your body directly to cool air for a long time Excessive exposure to cool air is bad for your health and should therefore be avoided 6 3 Room temperature adjustment To change room temperature Set temperature display and room temperature display Press the SET TEMP button and set the room temperature of your choice Press and button together the unit of temperature change C degree centigrade and F...

Page 8: ...ute setting During set clock mode or set timer mode press the MINUTE button will change the minute setting 10 Timer Hold Resume setting If 7 days timer is set then the word Timer Active is displayed To clear all the timers setting press and hold the HOLD button until the word Timer Active is not displayed To resume the timer setting after timers have been held press and hold the HOLD button until ...

Page 9: ...uilt into the unit Therefore there are occasions sometimes when the compressor does not start running immediately There are cases when it does not run for as long as 3 minutes ON OFF display is not lit up No display appears even when the ON OFF button is pressed 8 Fan runs but compressor do not run The set temperature of thermostat is excessively high for cooling For temperature control decrease t...

Page 10: ... 03 1 000 160 Btu h kcal h 81 900 109 200 163 800 218 400 20 700 27 600 41 300 55 100 Compressor output Indoor motor output 2 826 3 532 6 710 5 651 1 333 L S CFM CMM kW kW 1 667 3 167 2 x 8 0 70 0 200 765 PRC 24MYA PRC 24MYA 03 238 900 60 200 7 064 3 333 3 x 8 0 100 0 285 1 100 PRC 32MYA PRC 32MYA 03 341 200 8 600 10 066 4 750 2 667 8 0 35 0 395 PRC 12MYA PRC 12MYA 03 119 500 30 100 9 Special orde...

Page 11: ... the contact address telephone number on the operation manual before handing it to the customer HEAD OFFICE MITSUBISHI DENKI BLDG MARUNOUCHI TOKYO 100 0005 TELEX J24532 CABLE MELCO TOKYO Specifications subject to change without notice ...