Mitsubishi Electric PEA-RP200 GA Operation Manual Download Page 9

9

GB

D

F

I

NL

E

SW

P

˚C

˚C

AUTO OFF

6

7

AUTO OFF

7

˚C

˚C

AFTER

OFF

AUTO OFF

6

7

AFTER

TIMER

OFF

AUTO OFF

5

1

4

Timer Setting

Examples

If ON and OFF times have both been set at the simple timer, operation and display
are as indicated below.

Example 1:
Start the timer, with ON time set sooner than OFF time
ON Setting:

3 hours

OFF Setting:

7 hours

Example 2:
Start the timer, with OFF time is sooner than ON time
ON Setting:

5 hours

OFF Setting:

2 hours

3.6.3.

Using the Auto Off Timer

This timer begins countdown when the air conditioner starts, and shuts the air
conditioner off when the set time has elapsed.

Available settings run from 30 minutes to 4 hours, in 30-minute intervals.

Notes:
*1. Weekly Timer/Simple Timer/Auto Off Timer cannot be used at the same

time.

*2. The Auto Off  timer will not operate when any of the following conditions

is in effect.
The timer is off; the system is in malfunction state; a test run is in progress;
the remote controller is undergoing self-check or remote controller check;
the user is in the process of selecting a function; the user is in the proc-
ess of setting the timer; the system is under central control.  (Under these
conditions, On/Off operation is prohibited.)

s

How to Set the Auto Off Timer

1. Be sure that you are at a standard control screen, and that the Auto Off

timer indicator is visible in the display (at 

1

).

AFTER

OFF

AUTO OFF

PAR-21MAA

ON/OFF 

FILTER

CHECK

OPERATION

CLEAR

TEST

TEMP.

MENU

BACK

DAY

MONITOR/SET

CLOCK

ON/OFF

2

A 9

4

B

AFTER

OFF

AUTO OFF

3

1

2

Timer Setting

ON

Hr

AFTER

SIMPLE

˚C

˚C

OFF

Hr

AFTER

SIMPLE

SIMPLE

At 3 hours after

timer start

At Timer Start

At 7 hours after
timer start

Display shows the tim-
er’s ON setting (hours
remaining to ON).

Display changes to
show the timer’s OFF
setting (hours remain-
ing to OFF). The time
displayed is OFF set-
ting (7 hours) – ON
setting (3 hours) = 4
hours.

The air conditioner
goes off, and will re-
main off until someone
restarts it.

˚C

˚C

OFF

Hr

AFTER

SIMPLE

ON

Hr

AFTER

SIMPLE

˚C

˚C

SIMPLE

At 2 hours after

timer start

At Timer Start

At 5 hours after
timer start

Display shows the tim-
er’s OFF setting
(hours remaining to
OFF).

Display changes to
show the timer’s ON
setting (hours remain-
ing to ON). The time
displayed is ON set-
ting (5 hours) – OFF
setting (2 hours) = 3
hours.

The air conditioner
comes on, and will
continue to run until
someone turns it off.

When something other than the Auto Off Timer is displayed, set it to AUTO
OFF TIMER using the function selection of remote controller (see Installa-
tion Manual).

2. Hold down the Timer Menu button 

B

 for 

3 seconds

, so that the “Set Up”

appears on the screen (at 

2

).

(Note that each press of the button toggles the display between “Set Up”
and “Monitor”.)

3. Press the appropriate Set Time button 

A

 as necessary to set the OFF time

(at 

3

).

4. Press the Filter 

 button 

4

 to lock in the setting.

Note:
Your entry will be cancelled if you press the Mode (Return) button 

2

2

2

2

2

 before

pressing the Filter 

 button 

4

4

4

4

4

.

5. Press the Mode (Return) button 

2

 to complete the setting procedure and

return to the standard control screen.

6. If the air conditioner is already running, the timer starts countdown immedi-

ately. 

Be sure to check that the timer setting appears correctly on the

display.

s

Checking the Current Auto Off Timer Setting

1. Be sure that the “Auto Off” is visible on the screen (at 

1

).

2. Hold down the Timer Menu button 

B

 for 

3 seconds

, so that “Monitor” is

indicated on the screen (at 

4

).

• The timer remaining to shutdown appears at 

5

.

3. To close the monitor and return to the standard control screen, press the

Mode (Return) button 

2

.

s

To Turn Off the Auto Off Timer...

Hold down the Timer On/Off button 

9

 for 

3 seconds

, so that “Timer Off” ap-

pears (at 

6

) and the timer value (at 

7

) disappears.

Alternatively, turn off the air conditioner itself. The timer value (at 

7

) will disap-

pear from the screen.

s

To Turn On the Auto Off Timer...

Hold down the Timer On/Off button 

9

 for 

3 seconds

. The “Timer Off “ indica-

tion disappears (at 

6

), and the timer setting comes on the display (at 

7

).

Alternatively, turn on the air conditioner. The timer value will appear at 

7

.

WT05223X02_en

08.2.18, 5:37 PM

9

Summary of Contents for PEA-RP200 GA

Page 1: ...Air Conditioners INDOOR UNIT PEA RP170 200 250 WGA FOR USER OPERATION MANUAL For safe and correct use please read this operation manual thoroughly before operating the air conditioner unit GB ...

Page 2: ...2 GB D F SW I NL E P 2 Fig 2 0 1 A Air outlet B Air inlet C Air filter Fig 2 0 2 A B C A LCD remote controller ON OFF TEMP A 5 A C B D Fig 5 0 1 A Air outlet C Air filter B Air inlet D Air filter handle ...

Page 3: ...event damage to the unit Symbols put on the unit Indicates an action that must be avoided Indicates that important instructions must be followed Indicates a part which must be grounded Beware of electric shock This symbol is displayed on the main unit label Color yellow Warning Carefully read the labels affixed to the main unit 1 1 Installation s After you have read this manual keep it and the Ins...

Page 4: ...aler Otherwise a breakdown electric shock or fire may result When you notice exceptionally abnormal noise or vibration stop opera tion turn off the power switch and contact your dealer Do not over cool The most suitable inside temperature is one that is within 5 C of the outside temperature Do not leave handicapped people or infants sitting or standing in the path of the airflow from the air condi...

Page 5: ...nt time unless the simple or Auto Off timer is set If the simple or Auto Off timer is set shows the time remaining B Sensor indication Displayed when the remote controller sensor is used C Identifies the current operation Shows the operating mode etc Multilanguage display is supported D Centrally Controlled indicator Indicates that operation of the remote controller has been prohibited by a main c...

Page 6: ... keep the humidity low For heating Press the 2 2 2 2 2 operation mode button to bring up the HEAT display Regarding displays during heating operation DEFROST Displayed only during the defrosting operation STAND BY Displayed from the start of heating operation until the moment warm air blows out For automatic cooling heating Press the 2 2 2 2 2 operation mode button to bring up the AUTO display Cau...

Page 7: ... Selection of remote controller refer to Installation Manual s How to Set the Day of the Week and Time 1 Press the or Set Time button A to show display 2 2 Press the Timer On Off Set Day button 9 to set the day Each press advances the day shown at 3 Sun Mon Fri Sat 3 Press the appropriate Set Time button A as necessary to set the time As you hold the button down the time at 4 will increment first ...

Page 8: ...imer indicator is visible in the display at 1 When something other than the Simple Timer is displayed set it to SIMPLE TIMER using the function selection of remote controller see Installation Manual 2 Press the Timer Menu button B so that the Set Up appears on the screen at 2 Note that each press of the button toggles the display between Set Up and Monitor 3 Press the ON OFF button 1 to display th...

Page 9: ... Hr AFTER SIMPLE ON Hr AFTER SIMPLE C C SIMPLE At 2 hours after timer start At Timer Start At 5 hours after timer start Display shows the tim er s OFF setting hours remaining to OFF Display changes to show the timer s ON setting hours remain ing to ON The time displayed is ON set ting 5 hours OFF setting 2 hours 3 hours The air conditioner comes on and will continue to run until someone turns it o...

Page 10: ...ou can use the Func tion Selection of remote controller to select which type of lock to use For information about selecting the lock type see Installation Manual Specifically you can use either of the following two lock types 1 Lock All Buttons Locks all of the buttons on the remote controller 2 Lock All Except ON OFF Locks all buttons other than the ON OFF button Note The Locked indicator appears...

Page 11: ...acuum cleaner In the case of severe staining wash the filter in lukewarm water mixed with dissolved neutral detergent or water and then rinse off the detergent completely After washing dry it and fix it back into place Caution Do not dry the filter by exposing it to direct sunlight or warming it using fire etc Doing so can result in the deformation of the filter Washing it in hot water more than 5...

Page 12: ...mmand sent from the remote controller Find out if the remote controller was used Is the indicator lit Find out if the remote controller was used PLEASE WAIT is displayed in the remote controller An automatic startup test is being performed will last for about two minutes An error code is displayed in the remote controller A self diagnostic function is being performed to preserve the air conditione...

Page 13: ...ils consult with your dealer In some types of installation sites the installation of an earth leakage breaker is mandatory For details consult with your dealer Regarding transfer of installation When removing and reinstalling the air conditioner when you enlarge your home remodel or move consult with your dealer in advance to ascertain the cost of the professional engineering work required for tra...

Page 14: ......

Page 15: ......

Page 16: ...WT05223X02 Please be sure to put the contact address telephone number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN ...