316
(c) Resolution
The resolution is applied to the stored values and the set values of particular remote buffer memory areas as
described in the following table.
For applicable remote buffer memory areas, refer to the following.
(d) When Auto-setting at input range change (address: 1H. b0) is Enable (1)
When the input range is changed, the following remote buffer memory areas are set automatically according to
selected temperature sensor. Set the remote buffer memory areas again if necessary.
At the same time, the following remote buffer memory areas related to the input range is initialized to the
default value (0) automatically. Set the remote buffer memory areas again if necessary.
The remote buffer memory areas listed above are automatically set when CH
Input range (address: 100H,
130H, 160H, 190H) is changed and Initial data setting request flag (RY9) is turned on and off.
(e) When Auto-setting at input range change (address: 1H. b0) is Disable (0)
Sometimes the setting value of remote buffer memory (
Page 316, (5) (d)) might be out of setting range.
(When the setting range changes according to the change of the input range, the set value before the change
can turn out of the range.) In this case, a write data error (error code: 0004H) occurs in the remote buffer
memory area where the value turns out of the setting range. Change the input range after setting each remote
buffer memory area with values within the setting range after the input range change.
Resolution
Stored value
Set value
1
Value in 1
(
or digit) unit is stored.
Set a value in 1
(
or digit) unit.
0.1
Value in 0.1
(
) unit (tenfold value) is stored.
Value in 0.1
(
) unit (tenfold value).
Remote buffer memory area name
Remote buffer memory address
Reference
CH1
CH2
CH3
CH4
CH
Upper limit setting limiter
10AH
13AH
16AH
19AH
CH
Lower limit setting limiter
10BH
13BH
16BH
19BH
CH
Process alarm lower lower limit value
251H
25AH
263H
26CH
CH
Process alarm lower upper limit value
252H
25BH
264H
26DH
CH
Process alarm upper lower limit value
253H
25CH
265H
26EH
CH
Process alarm upper upper limit value
254H
25DH
266H
26FH
Remote buffer memory area name
Remote buffer memory address
Reference
CH1
CH2
CH3
CH4
CH
Set value (SV) setting
101H
131H
161H
191H
CH
Loop disconnection detection dead band
117H
147H
177H
1A7H
CH
Alert set value 1
224H
22CH
234H
23CH
CH
Alert set value 2
225H
22DH
235H
23DH
CH
Alert set value 3
226H
22EH
236H
23EH
CH
Alert set value 4
227H
22FH
237H
23FH
CH
Sensor two-point correction offset value (measured value)
284H
288H
28CH
290H
CH
Sensor two-point correction offset value (corrected value)
285H
289H
28DH
291H
CH
Sensor two-point correction gain value (measured value)
286H
28AH
28EH
292H
CH
Sensor two-point correction gain value (corrected value)
287H
28BH
28FH
293H
CH
AT bias setting
2A1H
2A3H
2A5H
2A7H
CH
Simultaneous temperature rise gradient data
2D1H
2D5H
2D9H
2DDH
CH
Simultaneous temperature rise dead time
2D2H
2D6H
2DAH
2DEH