22
Outdoor model
Indoor units number
Indoor units total capacity (Connectable)
✽
2
Indoor units total capacity (Simultaneous operation)
✽
2
Piping total length
Connecting pipe length
Height difference (Indoor ~ Outdoor)
Height difference (Indoor ~ Indoor)
Function
Capacity [Rated (Min~Max.) Hz]
✽
4
Dehumidification
Outdoor air flow
Power outlet
Running current
✽
4
Power input
Auxiliary heater
Crankcase heater
Power factor
✽
4
Starting current
✽
4
Compressor motor current
Fan motor current
Model
Output
Winding
resistance(at20
:
)
Model
Winding
resistance(at20
:
)
Dimensions W
O
H
O
D
Weight
Sound level (High/Low )
✽
3
Fan speed (High/Low )
✽
3
Fan speed regulator
✽
3
Refrigerant filling
capacity(R410A)
Refrigerating oil (Model)
Thermistor RT61
Thermistor RT62
Thermistor RT63
Thermistor RT68
Thermistor RT6A
Thermistor RT6B
Thermistor RT6C
Thermistor RT6D
Thermistor RT65
m
m
m
m
kW
R
/h
K
/h
A
A
W
A(kW)
W
%
A
A
A
W
"
"
mm
kg
dB
rpm
kg
cc
k
"
k
"
k
"
k
"
k
"
k
"
k
"
k
"
k
"
Compressor
Electrical
data
Fan
motor
Special
remarks
Capacity
System
Coefficient of performance(C.O.P)
Outdoor unit power supply
MXZ-A26WV -
E1
Single phase
230V,50Hz
2 to 3
Total capacity 54
Total capacity 54
Max. 50
Max. 25
10
10
25
—
—
99.0
9.44
0.2
TNB220FMCH (ROTARY)
2,000
U-V 1.41
V-W 1.41 W-U 1.41
PM8H60-UA
BLK-WHT 15.2
WHT-RED 15.2 RED-BLK 15.2
900
o
900
o
320 (+35)
69
2
3.5
870 (NEO22)
13.4 (at 100
:
)
10.0 (at 25
:
)
10.0 (at 25
:
)
10.0 (at 25
:
)
10.0 (at 25
:
)
10.0 (at 25
:
)
10.0 (at 25
:
)
10.0 (at 25
:
)
17.0 (at 50
:
)
Cooling
7.2 (2.9~8.5)
—
2,530
9.18
2,090 (720~2,560)
8.98
3.44
46/44
550/490
Heating
9.0 (2.6~11.0)
—
2,630
9.44
2,150 (530~3,050)
9.24
4.19
48/46
560/490
w w
w
w
w
w w
w
w
w
MXZ-A32WV -
E1
Single phase
230V,50Hz
2 to 4
Total capacity 54
Total capacity 54
Max. 70
Max. 25
10
10
25
—
—
99.0
9.62
0.2
TNB220FMCH (ROTARY)
2,100
U-V 1.41
V-W 1.41 W-U 1.41
PM8H60-UA
BLK-WHT 15.2
WHT-RED 15.2 RED-BLK 15.2
900
o
900
o
320 (+35)
70
2
3.5
870 (NEO22)
13.4 (at 100
:
)
10.0 (at 25
:
)
10.0 (at 25
:
)
10.0 (at 25
:
)
10.0 (at 25
:
)
10.0 (at 25
:
)
10.0 (at 25
:
)
10.0 (at 25
:
)
17.0 (at 50
:
)
Cooling
8.0 (3.7~9.2)
—
2,530
9.62
2,190 (810~2,580)
9.42
3.65
46/44
550/490
Heating
9.4 (3.4~11.6)
—
2,630
8.48
1,930 (590~3,230)
8.28
4.87
48/46
560/490
TEST CONDITIONS COOLING INDOOR
DB27.0°C WB19.0°C
OUTDOOR DB35.0°C WB24.0°C
HEATING INDOOR
DB20.0°C
OUTDOOR DB 7.0°C WB 6.0°C
NOTE: Test conditions are based on ISO5151 (Refrigerant piping length (one way): 5m)
w
Reference value
✽
1 Electrical data is for only outdoor unit.
✽
2 However, please refer to “INDOOR/OUTDOOR CORRESPONDENCE TABLE” of page 8 or 9 for the combination.
✽
3 These specifications are when all indoor units are operating.
✽
4 Measured under rated operating frequency.
OB319--1.qxp 03.12.3 0:55 PM Page 22