SPECIFICATION
3
Item
Outdoor model
Indoor type
Non-Duct (09+09)
Duct (09+12)
Capacity
Power
consumption
EER
SEER
HSPF IV (V)
COP
External finish
Power supply
Max. fuse size (time delay)
Min. circuit ampacity
Fan motor
Compressor
Refrigerant control
Sound level
Defrost method
Dimensions
Weight
Remote controller
Control voltage (by built-in transformer)
Refrigerant piping
Valve size
Connection method
Refrigerant charge (R410A)
Refrigeration oil (Model)
Model
Winding resistance (at 68°F)
Ω
W
D
H
Liquid
Gas
Indoor
Outdoor
Btu/h
Btu/h
Btu/h
W
W
W
V, phase, Hz
A
A
F.L.A
R.L.A
L.R.A
dB(A)
in.
in.
in.
lb.
in.
in.
lb.
oz.
Cooling
Heating 47
Heating 17
Cooling
Heating 47
Heating 17
Cooling
Cooling
Heating
Heating
MXZ-2B20NA, -
1
Munsell 3.0Y 7.8/1.1
208/230, 1, 60
20
15
0.96
SNB130FQBH1
U-V 0.98 V-W 0.98 W-U 0.98
10.1
15
LEV
49/51
Reverse cycle
33-1/16
13
27-15/16
130
Wireless type
12-24 V DC
Not supplied (optional parts)
1/4
A,B: 3/8
Flared
Flared
5 lb. 15 oz.
23.7 (NEO22)
18,000
22,000
14,500
1,440
1,650
1,500
12.5
18.0
8.9 (7.0)
3.91
20,000
22,000
12,500
2,190
1,780
1,430
9.1
15.5
8.5 (6.9)
3.62
Cooling
Heating
Mode
1: "A" Cooling steady state at rated compressor speed
"B-2" Cooling steady state at rated compressor speed
"B-1" Cooling steady state at minimum compressor speed
Low ambient cooling steady state at minimum compressor speed
Intermediate cooling steady state at intermediate compressor speed
1: Standard rating-heating at rated compressor speed
2: Low temperature heating at maximum compressor speed
Maximum temperature heating at minimum compressor speed
High temperature heating at minimum compressor speed
Frost accumulation at rated compressor speed
Frost accumulation at intermediate compressor speed
Test
Indoor air condition Outdoor air condition
Dry bulb Wet bulb Dry bulb Wet bulb
80
80
80
80
80
70
70
70
70
70
70
67
67
67
67
67
60
60
60
60
60
60
95
82
82
67
87
47
17
62
47
35
35
(75)
(65)
(65)
(53.5)
(69)
43
15
56.5
43
33
33
Unit: °F
NOTE : Test conditions are based on ARI 210/240.