![Mitsubishi Electric MXZ-24UV-E1 Service Manual Download Page 2](http://html.mh-extra.com/html/mitsubishi-electric/mxz-24uv-e1/mxz-24uv-e1_service-manual_1810967002.webp)
2
TECHNICAL CHANGES
1
MXZ-24UV -
➔
MXZ-24UV -
1. Combinations of the connectable indoor units have increased.
2. Noise filter P.C. board has changed to improve the capacity for protecting the inverter-controlled circuit when the
voltage higher than the rated one is aupplied with the inverter-controlled circuit.
3. Noise filter P.C. board for “E1” and “E2” are not interchangeable.
4. Service parts have been changed as follows according to above change;
•The value of R(resistor)has changed. 10
Ω
➔
20
Ω
•TB6(terminal block) has been removed.
E2
E1
OB287--1.qxp 03.1.16 10:29 AM Page 2