33
11-4. TROUBLE CRITERION OF MAIN PARTS
MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH
MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH
Part name
Check method and criterion
Figure
Defrost thermistor (RT61)
Fin temperature
thermistor (RT64)
Ambient temperature
thermistor (RT65)
Outdoor heat exchanger
temperature thermistor
(RT68)
Measure the resistance with a tester.
Refer to 11-6. “Test point diagram and voltage”, 1. “Inverter P.C.
board”, for the chart of thermistor.
Discharge temperature
thermistor (RT62)
Measure the resistance with a tester. Before measurement, hold the
thermistor with your hands to warm it up.
Refer to 11-6. “Test point diagram and voltage”, 1. “Inverter P.C.
board”, for the chart of thermistor.
Compressor
Measure the resistance between terminals using a tester.
(Temperature: -10 ~ 40°C)
Normal (
Ω
)
MUZ-SF25 MUZ-SF35 MUZ-SF42 MUZ-SF50
U-V
U-W
V-W
1.20 ~ 1.72 1.36 ~ 1.93 1.52 ~ 2.17 0.78 ~ 1.11
Outdoor fan motor
Measure the resistance between lead wires using a tester.
(Temperature: -10 ~ 40°C)
Color of lead wire
Normal (
Ω
)
MUZ-SF25/35/42
MUZ-SF50
RED – BLK
BLK – WHT
WHT – RED
29 ~ 42
12 ~ 17
R. V. coil (21S4)
Measure the resistance using a tester. (Temperature: -10 ~ 40°C)
Normal (k
Ω
)
1.19 ~ 1.78
Expansion valve coil
(LEV)
Measure the resistance using a tester. (Temperature: -10 ~ 40°C)
MUZ-SF25/35/42
Color of lead wire
Normal (
Ω
)
WHT – RED
37 ~ 54
RED – ORN
YLW – BRN
BRN – BLU
Measure the resistance using a tester. (Temperature: -10 ~ 40°C)
MUZ-SF50
Color of lead wire
Normal (
Ω
)
RED – ORN
37 ~ 54
RED – WHT
RED – BLU
RED – YLW
Defrost heater
MUZ-SF•VEH
Measure the resistance using a tester.
(Temperature: -10 ~ 40°C)
Normal (
Ω
)
349 ~ 428
W
U
V
WHT
RED BLK
W
U
V
WHT
RED BLK
LEV
WHT
RED
ORN
YL
W
BRN
BLU
RED
(+12V)
YLW
BLU
WHT
ORN
LEV
OBH629