13-2. MUZ-HR42VF MUZ-HR50VF
NOTE
: Turn OFF the power supply before disassembly.
Photos:
MUZ-HR42VF
OPERATING PROCEDURE
PHOTOS
1. Removing the cabinet
(1) Remove the screw fixing the service panel.
(2) Pull down the service panel and remove it.
(3) Disconnect the power supply cord and indoor/outdoor
connecting wire.
(4) Remove the screws fixing the top panel.
(5) Remove the top panel.
(6) Remove the screws fixing the cabinet.
(7) Remove the cabinet.
(8) Remove the screws fixing the back panel.
(9) Remove the back panel.
Photo 1
Photo 2
55
Back
panel
Service
panel
Screws of the
cabinet
Screws of the
top panel
Screw of the
cabinet
Screws
of the
back
panel
Screws of
the terminal block
support and the
back panel
Screws of the
service panel
Direction to
remove
Hooks
Screws of the
top panel
Screws of the
cabinet
OBH823