4
3
SPECIFICATION
Outdoor unit model
MUZ-FH06NA
MUZ-FH06NAH
MUZ-FH09NA
MUZ-FH09NAH
MUZ-FH12NA
MUZ-FH12NAH
MUZ-FH15NA
MUZ-FH15NAH
MUZ-FH18NA
MUZ-FH18NAH
MUZ-FH18NA2
MUZ-FH18NAH2
Capacity
Rated (Minimum~Maximum)
Cooling 1
Btu/h
6,000
(1,700 ~ 9,000)
9,000
(1,700 ~ 12,000)
12,000
(2,500 ~ 13,600)
15,000
(6,450 ~ 19,000)
17,200
(6,450 ~ 21,000)
Heating 47 1
Btu/h
8,700
(1,600 ~ 14,000)
10,900
(1,600 ~ 18,000)
13,600
(3,700 ~ 21,000)
18,000
(5,150 ~ 24,000)
20,300
(5,150 ~ 30,000)
Capacity
Rated (Maximum)
Heating 17 2
Btu/h
5,900 (10,700) 6,700 (12,200)
8,000(13,600) 11,000 (18,000)
13,700 (20,300)
Power consumption
Rated (Minimum~Maximum)
Cooling 1
W
315
(100 ~ 560)
560
(100 ~ 1,000)
870
(170 ~ 1,150)
1,200
(410 ~ 2,200)
1,430
(410 ~ 2,220)
1,375
(410 ~ 2,220)
Heating 47 1
W
545
(110 ~ 1,270)
710
(110 ~ 1,470)
950
(280 ~ 2,300)
1,300
(430 ~ 3,360)
1,720
(430 ~ 3,390)
Power consumption
Rated (Maximum)
Heating 17 2
W
500 (1,000)
600 (1,440)
720 (1,900) 1,020 (2,480)
1,320 (2,800)
EER
1
[SEER]
3
Cooling
19.1 [33.1]
16.1 [30.5]
13.8 [26.1]
12.5 [22.0]
12.0 [21.0]
12.5 [21.0]
HSPF IV
4
Heating
NA:
13.5
NA:
13.5
NA:
12.5
NA:
12.0
NA:
12.0
NA2:
12.0
NAH:
12.5
NAH:
12.5
NAH:
11.5
NAH:
11.0
NAH:
11.0
NAH2:
11.0
COP Heating
1 4.68
4.50
4.20
4.06
3.46
Power supply
V , phase , Hz
208/230, 1 , 60
Max. fuse size (time delay)
A
15
20
Min. circuit ampacity
A
11
16
Fan motor
F.L.A
0.50
0.93
Compressor
Model
SNB092FQAMT
SNB140FQUMT
SNB172FQKMT
R.L.A 8.2
12.0
L.R.A 10.3
15.0
Refrigeration oil L (Model)
0.35 (FV50S)
0.35 (FV50S)
0.40 (FV50S)
Refrigerant control
Linear expansion valve
Sound level
1
Cooling dB(A)
47
48
49
51
52
Heating dB(A)
48
49
51
55
55
Defrost method
Reverse cycle
Dimensions
W
in.
31-1/2
33-1/16
D
in.
11-1/4
13
H
in.
21-5/8
34-5/8
Weight Ib.
81
83
124
External
fi
nish
Munsell 3Y 7.8/1.1
Remote controller
Wireless type
Control voltage (by built-in transformer) VDC
12 - 24
Refrigerant piping
Not supplied
Refrigerant pipe size
(Min. wall thickness)
Liquid in.
1/4
(0.0315)
Gas
in.
3/8 (0.0315)
1/2 (0.0315)
Connection meth-
od
Indoor Flared
Outdoor Flared
Between the indoor
& outdoor units
Height difference ft.
40
50
Piping length
ft.
65
100
Refrigerant charge (R410A)
2 lb. 9 oz.
3 lb. 7 oz.
NOTE
: Test conditions are based on AHRI 210/240.
1: Rating conditions (Cooling) — Indoor: 80
˚
FDB, 67
˚
FWB, Outdoor: 95
˚
FDB, (75
˚
FWB)
(Heating) — Indoor: 70
˚
FDB, 60
˚
FWB, Outdoor: 47
˚
FDB, 43
˚
FWB
2:
(Heating) — Indoor: 70
˚
FDB, 60
˚
FWB, Outdoor: 17
˚
FDB, 15
˚
FWB
OBH684C