6
Outdoor model
MUZ-DW25VF
MUZ-DW35VF
MUZ-DW50VF
Power supply
Single phase, 230 V, 50 Hz
Capacity Rated (Min.- Max.)
Cooling
kW
2.5(0.5-2.9)
3.4(0.9-3.4)
5.0(1.3-5.0)
Heating
3.15(0.7-3.5)
3.6(0.9-3.7)
5.4(1.4-6.5)
Breaker Capacity
A
10
12
Electrical data
Power input *1 (Set)
Cooling
W
800
1,210
2,050
Heating
850
975
1,550
Running current *1 (Set)
Cooling
A
4.0
5.7
9.0
Heating
4.6
4.9
7.0
Power factor *1 (Set)
Cooling
%
86
92
99
Heating
80
86
96
Starting current *1 (Set)
A
4.6
5.7
9.0
Coefficient of performance
(COP) *1 (Set)
Cooling
3.13
2.81
2.44
Heating
3.70
3.70
3.50
Compressor
Model
KVB059FTMMC
KVB073FUXMC
SVB130FBBMT
Output
W
490
550
900
Current *1
Cooling
A
3.37
5.40
8.51
Heating
3.67
4.15
6.31
Refrigeration oil (Model)
L
0.27 (FW68S)
0.35 (FW68S)
Fan motor
Model
RC0J20-BC
RC0J50-NC
Current *1
Cooling
A
0.23
0.30
Heating
0.25
0.27
Dimensions W × H × D
mm
699 × 538 × 249
800 × 550 × 285
Weight
kg
23
24
35
Special remarks
Dehumidification
Cooling
L/h
0.5
1.1
2.2
Air flow
*1
Cooling
High
m
3
/h
1,818
1,932
2,124
Low
990
1,050
1,038
Heating
High
1,932
2,052
2,034
Med.
1,680
1,788
1,710
Low
1,260
1,350
1,332
Sound level *1
Cooling
dB(A)
50
51
50
Heating
50
51
Fan speed
Cooling
High
rpm
840
970
Low
480
510
Heating
High
890
930
Med.
780
790
Low
600
630
Fan speed regulator
3
Refrigerant filling capacity (R32)
kg
0.50
0.55
0.97
NOTE
: Test conditions are based on ISO 5151.
Cooling: Indoor
Dry-bulb temperature 27°C
Wet-bulb temperature 19°C
Outdoor Dry-bulb temperature 35°C
Wet-bulb temperature 24°C
Heating: Indoor
Dry-bulb temperature 20°C
Wet-bulb temperature 15°C
Outdoor Dry-bulb temperature 7°C
Wet-bulb temperature 6°C
Refrigerant piping length (one way): 5 m
*1 Measured under rated operating frequency.
SPECIFICATION
4