background image

En-6

I-

SAVE OPERATION 

1

Press 

 during COOL, ECONO COOL, or HEAT 

mode to select i-save mode.

2

Set the temperature, fan speed, and airfl ow direction.

•  The same setting is selected from the next time by simply pressing 

 .

•  Two settings can be saved. (One for COOL/ECONO COOL, one for 

HEAT)

•  Select the appropriate temperature, fan speed, and airflow direction 

according to your room.

•  Normally,  the  minimum  temperature  setting  in  HEAT  mode  is  16°C. 

However, during i-save operation only, the minimum temperature set-

ting is 10°C.

Press 

 again to cancel i-save operation. 

•  i-save operation also is cancelled when the MODE button is pressed.

i-save operation

•  A simplified set back function enables to recall the preferred (preset) setting 

with a single push of the 

 button. Press the button again and you can go 

back to the previous setting in an instance.

•  i-save operation cannot be set on the weekly timer.

Example of use:

1. Low energy mode

Set the temperature 2°C to 3°C warmer in COOL and cooler in HEAT mode. 

This setting is suitable for unoccupied room, and while you are sleeping.

2. Saving frequently used settings

Save your preferred setting for COOL/ECONO COOL and HEAT. This ena-

bles you to select your preferred setting with a single push of the button.

Note:

When using the multi system MXZ-8A140, the temperature cannot be set to 

10°C. Even if the temperature is set to 10°C, the air conditioner will operate 

at 16°C.

E

CONO COOL OPERATION 

Press 

 during COOL mode 

 page 4 

 to start 

ECONO COOL operation.

The unit performs swing operation vertically in various cycles according to the 

temperature airflow.

Press 

 again to cancel ECONO COOL operation. 

•  ECONO COOL operation is also cancelled when the VANE button is 

pressed.

What is “ECONO COOL”?

Swing airfl ow (change of air fl ow) makes you feel cooler than stationary airfl ow.

The set temperature and the airfl ow direction are automatically changed by the 

microprocessor.

It is possible to perform cooling operation with keeping comfort.

As a result energy can be saved.

1

Press 

 or 

 during operation to set the timer. 

 (ON timer) :    The unit turns ON at the set time.
 (OFF timer) :  The unit turns OFF at the set time.

 or 

 blinks.

*  Make sure that the current time and day are set correctly. 

 

Page 3

 

2

Press 

 (Increase) and 

 (Decrease) to set the 

time of timer. 

Each press increases or decreases the set time by 10 minutes.

•  Set the timer while 

 

or

 

 

is blinking.

3

Press 

 or 

 again to cancel timer.

Note:

•  ON and OFF timers can be set together.   mark indicates the order of timer 

operations.

•  If power failure occurs while ON/OFF timer is set, see 

 page 4 

 “Auto restart 

function”.

T

IMER OPERATION (ON/OFF TIMER)

JG79A965H03_en.indd   6

9/3/2015   1:54:10 PM

Summary of Contents for MSZ-SF25VE2

Page 1: ...d in tutta sicurezza questo apparecchio leggere il presente libretto d istruzioni prima dell uso MANUAL DE INSTRUCCIONES Para los clientes Para utilizar esta unidad de forma correcta y segura lea previamente estas instrucciones de funcionamiento BEDIENINGSINSTRUCTIES Voor de klant Om dit apparaat correct en veilig te kunnen gebruiken moet u deze be dieningsinstructies voor gebruik eerst doorlezen ...

Page 2: ...ed physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appli ance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the ...

Page 3: ... a new one may cause overheat ing leakage or explosion If the battery fluid comes in contact with your skin or clothes wash them thoroughly with clean water If the battery fluid comes in contact with your eyes wash them thor oughly with clean water and immediately seek medical attention Ensure that the area is well ventilated when the unit is operated together with a combustion appliance Inadequate ...

Page 4: ...tion display section ON OFF operate stop button Temperature buttons Page 4 Operation select button Page 4 ECONO COOL button Page 6 FAN speed control button Page 5 VANE control button Page 5 TIME TIMER set buttons Pages 3 6 Increase time Decrease time CLOCK button Page 3 RESET button Page 3 Lid Slide the lid down to open the remote controller Slide it down further to get to the weekly timer buttons...

Page 5: ...ion If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power When timer is set timer setting is cancelled and the unit starts operation when power is resumed If you do not want to use this function please consult the service rep...

Page 6: ...es with your hands causes them to mal function When the breaker is turned on the horizontal vanes position will be reset in about a minute then the operation will start The same is true in the emergency cooling operation When the horizontal vanes seem to be in an abnormal position see page 9 AUTO Silent Low Med High Super High AUTO 1 2 3 4 5 SWING Airflow direction AUTO The vane is set to the most...

Page 7: ...ngle push of the button Note When using the multi system MXZ 8A140 the temperature cannot be set to 10 C Even if the temperature is set to 10 C the air conditioner will operate at 16 C ECONOCOOLOPERATION Press during COOL mode page 4 to start ECONO COOL operation The unit performs swing operation vertically in various cycles according to the temperature airflow Press again to cancel ECONO COOL ope...

Page 8: ...ttings will not be cleared when the weekly timer is turned OFF Checking weekly timer setting 1 Press to enter the weekly timer setting mode blinks 2 Press or to view the setting of the particular day or number Press to exit the weekly timer setting Note When all days of the week are selected to view the settings and a different set ting is included among them will be displayed which was blink ing ...

Page 9: ...ation in the air conditioner which will contribute to the growth of fungi such as mold It is therefore recommended to clean air filters every 2 weeks Front panel Air cleaning filter Electrostatic anti allergy enzyme filter option Every 3 months Remove dirt by a vacuum cleaner When dirt cannot be removed by vacuum cleaning Soak the filter and its frame in lukewarm water before rinsing it After washing ...

Page 10: ...n starts to rotate it stops soon When the outside temperature is low during cooling operation the fan operates intermittently to maintain sufficient cooling capacity Water leaks from the outdoor unit During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation water condensed on the heat exchanger drips down In the heating ope...

Page 11: ... as mold 2 Press to stop the operation 3 Turn off the breaker and or disconnect the power sup ply plug 4 Remove all batteries from the remote controller When using the air conditioner again 1 Clean the air filter Page 8 2 Check that the air inlet and outlet of the indoor and outdoor units are not blocked 3 Check that the earth is connected correctly 4 Refer to the PREPARATION BEFORE OPERATION and f...

Page 12: ...и по долу за употреба в жилищни търговски и леки промишлени условия Note Its serial number is on the nameplate of the product Hinweis Die Seriennummer befindet sich auf dem Kennschild des Produkts Remarque Le numéro de série de l appareil se trouve sur la plaque du produit Opmerking het serienummer staat op het naamplaatje van het product Nota El número de serie se encuentra en la placa que contie...