18
ABSENCE DETECTION ( )
(1) To activate this No occupancy energy-saving mode, press SENSOR button until
appears on the operation display
(2) To activate this No occupancy Auto-OFF mode,
appears on the operation display of
(3) Press SENSOR button again to cancel the ABSENCE DETECTION.
Even if the unit is turned OFF due to No occupancy Auto-OFF mode, the display of the remote controller remains to indicate the
unit is in operation. Press STOP/OPERATE(OFF/ON) button then press STOP/OPERATE(OFF/ON) button again to restart operation.
When OFF timer is set, a priority is given to OFF timer.
No occupancy energy saving mode or No occupancy Auto-OFF mode are not available during POWERFUL operation.
The unit will not be turned off if no one is detected during normal operation mode, even though No occupancy Auto-OFF mode
is activated.
Energy-
saving
mode
Auto-OFF
mode
No
occupancy
detected
Occupancy
detected
About
10 min.
Normal
Normal
Normal
About 1 HR.
Saving energy
Saving more
Turn OFF
Saving energy
Cancel
press SENSOR button until
of the remote controller.
the remote controller.
This function automatically changes the operation to No occupancy energy-saving mode or No occupancy Auto-OFF mode
when nobody is in the room.
9-10. AIR FLOW CONTROL MODE
AIRFLOW CONTROL mode offers air conditioning according to a location of an occupant in a room detected by i-see SENSOR.
(1) Press DIRECTION button during COOL, DRY, HEAT or AUTO mode to activate the AIRFLOW CONTROL mode.
This mode is only available when the i-see control mode is effective.
(2) Each press of DIRECTION button changes AIRFLOW CONTROL in the following order:
(INDIRECT) : An occupant will be less exposed to direct air
À
ow.
(DIRECT) : Mainly the vicinity of an occupant will be air-conditioned.
(EVEN) : The unit learns the area where an occupant spend most of the time, and evens out the temperature
of that area.
Horizontal and vertical airflow directions will be automatically selected.
When more than a couple of people are in a room, the AIRFLOW CONTROL mode may work less effectively.
If you still feel uncomfortable with the air direction determined by the INDIRECT mode, adjust the air direction manually.
(3) Cancelling the i-see control mode automatically cancels the AIRFLOW CONTROL mode.
The AIRFLOW CONTROL mode is also cancelled when the VANE CONTROL or WIDE VANE buttons is pressed.
(INDIRECT) (DIRECT) (EVEN) (OFF)
NOTE:
OBH766