● OPERATING INSTRUCTIONS ●
EN
EN-6
In the following cases, stop using the air conditioner and consult your dealer.
• When water leaks or drips from the indoor unit.
• When the operation indicator lamp blinks.
• When the breaker trips frequently.
• The remote control signal is not received in a room where an electronic ON/OFF type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.
• Operation of the air conditioner interferes with radio or TV reception. An amplifi er may be required for the affected device.
• When an abnormal sound is heard.
• When any refrigerant leakage is found.
S
PECIFICATIONS
W
HEN YOU THINK THAT TROUBLE HAS OCCURRED
DB: Dry Bulb
WB: Wet Bulb
Indoor
Outdoor
Cooling
Upper limit
32°C DB
23°C WB
46°C DB
—
Lower limit
21°C DB
15°C WB
-10°C DB
—
Heating
Upper limit
27°C DB
—
24°C DB
18°C WB
Lower limit
20°C DB
—
-10°C DB
-11°C WB
Note:
Rating condition
Cooling — Indoor:
27°C DB, 19°C WB
Outdoor: 35°C DB
Heating — Indoor:
20°C DB
Outdoor: 7°C DB, 6°C WB
Guaranteed operating range
Model
Indoor
MSZ-HR25VF
MSZ-HR35VF
MSZ-HR42VF
MSZ-HR50VF
Outdoor
MUZ-HR25VF
MUZ-HR35VF
MUZ-HR42VF
MUZ-HR50VF
Function
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Power supply
~ /N, 230 V, 50 Hz
Capacity
kW
2.5
3.15
3.4
3.6
4.2
4.7
5.0
5.4
Input
kW
0.80
0.85
1.21
0.975
1.34
1.30
2.05
1.55
Weight
Indoor
kg
8.5
9
Outdoor
kg
23
24
34
35
Refrigerant fi lling capacity (R32)
kg
0.40
0.45
0.70
0.80
IP code
Indoor
IP 20
Outdoor
IP 24
Permissible excessive
operating pressure
LP ps
MPa
2.77
HP ps
MPa
4.17
Noise level (SPL)
Indoor (Super High/
High/Med./Low)
dB(A) 43/37/30/21 43/37/30/21 46/38/31/22 44/37/30/21 44/39/34/24 46/40/32/24 45/40/36/28 47/41/34/27
Outdoor
dB(A)
50
50
51
51
50
51
50
51