![Mitsubishi Electric MSZ-HC25VA Service Manual Download Page 31](http://html.mh-extra.com/html/mitsubishi-electric/msz-hc25va/msz-hc25va_service-manual_1810723031.webp)
31
OPERATING PROCEDURE
PHOTOS
4. Removing the vane motor
(1) Turn the breaker OFF.
(2) Remove the panel (refer to 1.) and the corner box.
(3) Remove the indoor electronic control P.C. board hold-
er (refer to 2.).
(4) Remove the screws of vane motor and remove the
vane motor.
(5) Disconnect the connector from vane motor.
5.
Removing the indoor fan motor, the indoor coil
ther-
mistor, and the line flow fan
(1) Remove the panel (refer to 1.) and the corner box.
(2) Remove the indoor electronic control P.C. board holder (refer
to 2.) and the electrical box (refer to 3.).
(3) Remove the drain hose from the nozzle assembly, and
remove the nozzle assembly.
(4) Loosen the screw fixing the line flow fan.
(5) Remove the screws fixing the motor bed. Lift the right
side of motor bed a little, and pull right to remove the
fan motor together with motor band/bed.
(6) Remove the indoor coil thermistor from the heat
exchanger
( )
MSZ-HC35VA(B)-
E2
Install the indoor coil thermistor in its former position
when assembling it. (Photo 7)
(7) Remove the screws fixing the left side of the heat
exchanger.
(8) Lift the left side of the heat exchanger, and pull out the
line flow fan to the lower-left.
Photo 6
Photo 4
Screws of the vane motor
Screws of the motor bed
Photo 5
Screws of the line flow fan
Indoor coil
thermistor (sub)
RT13
Indoor coil
thermistor (main)
RT12
Photo 7