En-6
Heat exchanger
• Wear gloves to protect your
hands.
• Use the QUICK CLEAN KIT
(option).
Parts Number
MAC-093SS-E
• Refer to the instructions described
in the QUICK CLEAN KIT for details.
Front panel
Instructions:
1. Lift the front panel until a “click” is heard.
2. Hold the hinges and pull to remove as shown in the above illustration.
• Wipe with a soft dry cloth or wash it with water.
• Do not soak it in water for more than two hours.
• Dry it well in shade before installing it.
3. Install the panel by following the removal
procedure in reverse. Close the front panel
securely and press the positions indicated
by the arrows.
Hole
Hinge
Hold the tab
Air cleaning fi lter
(Anti-Allergy Enzyme Filter, option)
Back side of air fi lter
•
Clean every 3 months.
• Soak the fi lter together with its frame in lukewarm water and wash
it.
• After washing, dry it well in shade and put it back to its original position.
Install all tabs of the air fi lter.
• Replace it with a new air cleaning
fi lter
every year
for best perform-
ance.
• Parts Number
MAC-415FT-E
What is “Catechin air fi lter” ?
Catechin is a biofl avonoid that is found in green tea that has both antivi-
ral and antioxidant qualities. In addition to these benefi ts, Catechin also
offers excellent deodorizing characteristics. Catechin air fi lter uses this
compound to not only improve air quality but also prevent the spread of
bacteria and viruses in the room.
Note:
Clean the fi lters regularly for best performance and to reduce power
consumption.
Air outlet and Fan (before cleaning, make sure that the fan is stopped)
Pull to remove from the air fi lter
Air fi lter (Catechin air fi lter)
•
Clean every 2 weeks
• Remove dirt by a vacuum cleaner, or wash with water.
• Dry it well in shade before installing it.
C
LEANING
1
Turn the horizontal vane upward.
Then, remove it as shown in
➀
and
➁
.
4
Put the vertical vanes back to
their original positions correctly
one by one, into their respective
guide.
• Push the vanes until they click into place.
3
Clean the air outlet and fan.
• Wipe with a soft dry cloth.
Clean the fan.
• Use the QUICK CLEAN KIT (option).
Parts Number
MAC-093SS-E
• Refer to the instructions described in the
QUICK CLEAN KIT for details.
5
Install the horizontal vane by
following the removal procedure
in reverse.
• If the horizontal vane is not installed cor-
rectly, all LED lamps blink when power is
turned on.
1
2
Unlock
• Switch off the power supply or turn off the breaker before cleaning.
• Be careful not to touch the metal parts with your hands.
• Do not use benzine, thinner, polishing powder, or insecticide.
• Use only diluted mild detergents.
• Do not expose parts to direct sunlight, heat, or fl ames to dry.
• Do not use water hotter than 50°C.
Guide
2
Swing out the two vertical vanes
one by one.
• Make sure that the horizontal vane is re-
moved.
Note:
Do not apply excessive force to the fan or fan guard.