•
model has been added.
•9-2. Failure mode recall function has been changed.
•RoHS PARTS LIST has been added.
E3
2
1
TECHNICAL CHANGES
MSZ-A09YV -
➔
MSZ-FA25VA -
MSZ-A12YV -
➔
MSZ-FA35VA -
E1
E1
E1
E1
12. PLASMA DEODORIZING/AIR PURIFYING filter units have been added.
13. i-see Sensor has been added.
(i-see control operation and AREA setting have been added.)
14. Air cleaning filer has been removed.
15. Signal of remote controller has been changed. (It is not available for the conventional models.)
16. Symbol on terminal block has been changed (to S1/S2/S3).
NOTE: Do not remove the vane motor from the motor unit.
Do not disassemble the horizontal vane motor unit.
11. Front panel driving motor unit which opens and closes the front panel has been added.
Front panel opening/closing
output gear
NOTE: Do not disassemble the front panel driving motor unit.
Generalized stepping motor
10. The vertical vane motor unit has been added.
An external gear is added to the generalized stepping motor.
The unit is structured so that the driving torque and stopping torque would increase.
Generalized stepping motor
NOTE: Do not remove the vane motor from the motor unit.
Do not disassemble the vertical vane motor unit.
1. Indication of capacity has been changed.(BTU base
➔
kW base)
2. Controller method between indoor and outdoor has been changed.
3. Power supply method has been changed (change to supply from outdoor unit).
4. Power supply cord has been removed.
5. Indoor electronic control P.C. board has been changed.
6. Position of terminal block has been changed.
7. Indoor fan motor has been changed. ( AC
➔
DC)
8. Indoor heat exchanger has been changed.
9. The horizontal vane motor unit has been changed.
An external gear is added to the generalized stepping motor.
The unit is structured so that the driving torque and stopping torque would increase.
•
model has been added.
Color of BOX and CORNER BOX has been changed to white.
E2
Revision:A
Revision:B
OB371B--1qxp 06.5.10 2:00 PM Page 2