![Mitsubishi Electric MSZ-EF18VGB Service Manual Download Page 42](http://html.mh-extra.com/html/mitsubishi-electric/msz-ef18vgb/msz-ef18vgb_service-manual_1810597042.webp)
42
Room temperature thermistor (RT11)
Indoor coil thermistor (RT12, RT13)
Temperature (°C)
Resistance (kΩ)
Indoor electronic
control P.C. board
Indoor power P.C. board
Fuse (F11)
Varistor (NR11)
Indoor fan motor
(CN211)
325 V DC
(–) GND (high-
voltage DC)
15 V DC
(+)3-6 V DC
(+)0 or 15 V DC
Connector to terminal
block (CN201)
Connector to indoor
electronic control P.C.
board (CN202)
Receiver P.C. board
Display P.C. board
Switch P.C. board
Reactor (L111)
5 V DC
12 V DC
GND
Timer short mode
point JPG JPS (Refer
to 8-1.)
To disable "Auto restart function",
cut the Jumper wire to JR77.
(Refer to 8-3.)
Emergency operation
switch (E.O.SW) (SW1)
Connector to power
P.C. board (CN102)
Room temperature ther-
mistor RT11 (CN111)
Vane motor
(CN151)
Indoor coil ther-
mistor RT12,
RT13 (CN112)
MSZ-EF18VGW-
E1
MSZ-EF22VGW-
E1
,
ET1
MSZ-EF25VGW-
E1
,
ET1
MSZ-EF35VGW-
E1
,
ET1
MSZ-EF42VGW-
E1
,
ET1
MSZ-EF50VGW-
E1
,
ET1
MSZ-EF18VGB-
E1
MSZ-EF22VGB-
E1
,
ET1
MSZ-EF25VGB-
E1
,
ET1
MSZ-EF35VGB-
E1
,
ET1
MSZ-EF42VGB-
E1
,
ET1
MSZ-EF50VGB-
E1
,
ET1
MSZ-EF18VGS-
E1
MSZ-EF22VGS-
E1
,
ET1
MSZ-EF25VGS-
E1
,
ET1
MSZ-EF35VGS-
E1
,
ET1
MSZ-EF42VGS-
E1
,
ET1
MSZ-EF50VGS-
E1
,
ET1
10-7. TEST POINT DIAGRAM AND VOLTAGE
1. Indoor electronic control P.C. board, indoor power P.C. board, receiver P.C. board and display P.C. board
OBH831A