45
Checking method and criterion
Part name
3. Trouble shooting procedure of main parts
(Simple check method of main parts)
MSZ-A09RV -
MUZ-A09RV -
MSZ-A12RV -
MUZ-A12RV -
E1
E1
E1
E1
Room
temperature
Indoor coil
thermistor
(main-auxiliary)
Defrost
thermistor
Discharge
temprature
thermistor
Fin temperature
thermistor
Compressor
Indoor fan
motor
Disconnect the connector and measure the resistance with a tester.
(Part temperature : 10
:
~30
:
)
normal
abnormal
8k
"
~20K
"
Open or short circuit
Disconnect the connector and measure the resistance with a tester.
(Part temperature : -10
:
~40
:
)
normal
abnormal
5k
"
~55K
"
Open or short circuit
Disconnect the connector and measure the resistance with a tester.
Before measurement, hold the termistor with your hands to warm it up.
(Part temperature : 20
:
~40
:
)
normal
abnormal
100k
"
~250K
"
Open or short circuit
Disconnect the connector and measure the resistance with a tester.
(Part temperature : -10
:
~80
:
)
normal
abnormal
5k
"
~30K
"
Open or short circuit
Disconnect the connector and measure the resistance between the terminals with a tester.
(Winding temperature : -10
:
~40
:
)
Measure the resistance between the terminals with a tester.
(Winding temperature : 10
:
~30
:
)
termina
(CN211)
normaL
abnormal
WHT-BLK
280
"
~304
"
BLK-RED
311
"
~338
"
Open or short circuit
2
3
W
U
V
1
WHT
Compressor motor
RED BLK
2
3
1
WHT
RED
BLK
normal
abnormal
0.82
"
~1.01
"
Open or short circuit