15
9-4. AUTO VANE OPERATION
1. Horizontal vane
(1) Vane motor drive
These models are equipped with a stepping motor for the horizontal vane. The rotating direction, speed, and angle of
the motor are controlled by pulse signals (approximately 12 V) transmitted from indoor microprocessor.
(2) How to set the vane angle
Press the
button.
Select “Vane·Louver·Vent. (Lossnay)” with
or
button, and press
button.
Press
or
button to go through the vane setting options: “Auto”, “Step 1”, “Step 2”, “Step 3”, “Step 4”, “Step 5”
and “Swing”, and select the desired setting.
Press
button to go back to the Main menu.
(3) Positioning
To confirm the standard position, the vane moves until it touches the vane stopper. Then the vane is set to the selected
angle.
Confirmation of standard position is performed in the following cases:
(a) When the operation starts or finishes (including timer operation).
(b) When the test run starts.
F1
F2
F3
F4
Cool
Room
Auto
Set temp.
Mode
Temp.
Fan
Fri
Press button to go through the fan speeds in the following order.
Auto
Low
Med.
Super High
High
F1
F2
F3
F4
Main
Main display:
Cursor
Page
Main menu
Vane·Louver·Vent. (Lossnay)
High power
Timer
Weekly timer
OU silent mode
F1
F2
F3
F4
Fri
Swing
Off
Off
Louver
Vent.
Vane
Auto
Auto
Swing
Step 1
Step 2
Step 4
Step 3
Swing
Step 5
9-3. FAN( )OPERATION
(1) Press
button. OFF/ON lamp will light up in green and the operation will start.
(2) Select FAN mode with
button.
(3) Press
button to select the desired fan speed. When AUTO, it becomes Low.
Only indoor fan operates. Outdoor unit does not operate.