preparation before operation
To stop the Emergency operation, press the Emergency
operation switch.
each time the siwtch is pressed, the unit alternates between
the emergency cooL mode and STop mode.
●
●
●
●
●
●
●
Batteries
Notes for using the remote controller
WHEN THE REMOTE CONTROLLER CANNOT
BE uSED (E
mergency operation)
when the signal does not operate the indoor unit, or the
display becomes dim, replace the batteries with new
alkaline batteries (Lr03)
reference for replacing batteries
The range that the signal can reach is about 6m when pointed
at the front of the indoor unit.
when the button is pressed, one or two beeps will be heard from
the indoor unit. if no sound is heard, operate again.
use the remote controller carefully.
if it is dropped, thrown or gets wet, it may not operate.
do not wring or press the remote controller, it may cause the
componets inside the remote controller damage.
Replace 2 batteries with new batteries of the same type.
Do not use rechargeable batteries.
To prevent from liquid leakage, take out all batteries when the
remote controller is not going to be used for a long time.
The service life of an alkaline battery is about 1 year.
However, since the recommended usable time limit is indicated
(month / year) on the bottom of the battery, a battery the time
limit of which is approaching may become exhaust sooner.
When the signal does not operate the indoor unit and the
display becomes dim, press the button and the OPERATION
DISPLAY SECTION display all patterns, at the same time the
air conditioner runs as "I FEEL..." AUTO-OPERATION mode.
when the batteries of the remote controller run out or
remote controller malfunctions, emergency operation can
be done using the emergency operation switch.
Each time the siwtch is pressed, the unit alternates
between the Emergency COOL mode and STOP mode.
However, when the EMERGENCY OPERATION
switch is once pressed, the unit will operate in test run
for 30 minutes and then the operation mode shifts to
EMERGENCY MODE.
Details of operation are as shown below. However, the
temperature control does not work for about 30 minutes at
first and the unit is set to the continuous operation mode
with the fan speed set to"Medium".
Press the Emergency operation switch.
Laying places
Laying the romote controller
●
The places where it is easy to operate and easily visible.
The places where children can not touch.
In rooms where inverter type fluorescent lamps are
used, the signal from the wireless remote controller
not be received.
NOTE
●
●
1
2
33
Details of operation
Set temperature
Fan speed
Horizontal vane
Vertical Vane
COOl
24
℃
Medium
Auto
Front
Emergeney operation
●