5
SPECIFICATION
3
Indoor model
Function
Indoor unit power supply
Air flow(High/Med. /Low
)
Power outlet
Running current
Power input
Power factor
Fan motor current
Model
Winding
resistance(at 20
:
)
Dimensions W
O
H
O
D
Weight
Air direction
Sound level(High/Med. /Low )
Fan speed(High/Med. /Low )
Fan speed regulator
Thermistor RT11(at 25
:
)
Thermistor RT12(at 25
:
)
Remote controller model
K
/h
A
A
W
%
A
"
mm
kg
dB
rpm
k
"
k
"
MSC-A07YV -
E1
Single phase
230V,50Hz
10
0.17
35
90
0.17
RC4V19-LA
WHT-BLK 413
BLK-RED 334
815
O
278
O
244
9
5
3
10
10
KP1A or KG3A
Cooling
474/372 /276
36/31 /25
900/750 /600
Heating
510/420 /342
36/31 /25
950/820 /700
MSC-A09YV -
E1
Single phase
230V,50Hz
10
0.17
35
90
0.17
RC4V19-LA
WHT-BLK 413
BLK-RED 334
815
O
278
O
244
9
5
3
10
10
KP1A or KG3A
Cooling
474/384 /306
36/31 /25
900/770 /650
Heating
588/456 /342
39/32 /25
1,050/870 /700
MSC-A12YV -
E1
Single phase
230V,50Hz
10
0.19
40
92
0.19
RC4V19-KA
WHT-BLK 316
BLK-RED 299
815
O
278
O
244
10
5
3
10
10
KP1A or KG3A
Cooling
582/444 /324
40/33 /26
930/760 /600
Heating
606/498 /396
39/33 /26
960/830 /700
Electrical
data
Fan
motor
Special
remarks
Capacity
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
NOTE: 1. Test conditions are based on ISO 5151.
Cooling : Indoor
DB27°C WB19°C
Heating : Indoor
DB20°C
Outdoor DB35°C WB24°C
OutdoorDB 7°C/WB 6°C
Indoor-Outdoor piping length 5m
2.Remote controller model KP1A and KG3A are the same in terms of specification.
W
Reference value
OB329-1.qxp 03.12.3 1:16 PM Page 5