● OPERATING INSTRUCTIONS ●

Installation place

Avoid installing the air conditioner in the following places.

•  Where there is much machine oil.

•  Salty places such as the seaside.

•  Where sulfi de gas is generated such as a hot spring.

•  Where oil is splashed or where the area is fi lled with oily smoke (such as cook-

ing areas and factories, in which the properties of plastic could be changed 

and damaged).

•  Where there is high-frequency or wireless equipment.

•  Where the air from the outdoor unit air outlet is blocked.

•  Where the operation sound or air from the outdoor unit does not bother the 

house next door.

Electrical work

•  Provide an exclusive circuit for the power supply of the air conditioner.

•  Be sure to observe the breaker capacity.

If you have any questions, consult your dealer.

I

NSTALLATION PLACE AND 

ELECTRICAL WORK

S

PECIFICATIONS

To prevent the effects 

of a fl uorescent lamp, 

keep as far apart as 

possible.

wall, etc.

Inverter-type 

fl uorescent lamp

Keep a space to 
prevent the pic-
ture distortion or 
the noise.

1 m 

or more

Radio

100 mm or 
more

Well- 
ventilated dry 
place

200/500 mm 
or more

TV

Cordless 
phone or 
Portable 
phone

3 m or 

more

1 m 

or more

The installation location of the outdoor unit should 

be at least 3 m away from the antennas for TV sets, 

radios, etc. In areas where the reception is weak, 

provide greater space between the outdoor unit and 

the antenna of the affected device if operation of the air 

conditioner interferes with radio or TV reception.

1

Set to the highest temperature in manual COOL mode, 

and operate for 3 to 4 hours. 

 Page 4 

•  This dries the inside of the unit.

•  Moisture in the air conditioner contributes to favorable conditions for 

growth of fungi, such as mold.

2

Press 

 to stop the operation.

3

Turn off the breaker and/or disconnect the power sup-

ply plug.

4

Remove all batteries from the remote controller.

When using the air conditioner again:

1

Clean the air fi lter. 

 Page 7 

2

Check that the air inlet and outlet of the indoor and 

outdoor units are not blocked.

3

Check that the earth is connected correctly.

4

Refer to the “PREPARATION BEFORE OPERATION”, 

and follow the instructions. 

 Page 3 

W

HEN THE AIR CONDITIONER IS NOT 

GOING TO BE USED FOR A LONG TIME

(50/60, 80)

Note:

1. Rating condition

  Cooling — Indoor: 

27°C DB, 19°C WB

   

Outdoor:  35°C DB

2. Noise measurement is carried out in accordance with JIS C9612 and ISO 

5151(T1).

Indoor

Outdoor

Cooling

Upper limit

35°C DB

24°C WB

46°C DB

Lower limit

21°C DB

15°C WB

21°C DB

Guaranteed operating range

DB:  Dry Bulb

WB: Wet Bulb

Model

Set name

MS-GF50VA

MS-GF60VA

MS-GF80VA

Indoor

MS-GF50VA

MS-GF60VA

MS-GF80VA

Outdoor

MU-GF50VA

MU-GF60VA

MU-GF80VA

Function

Cooling

Cooling

Cooling

Power supply

~ /N, 230 V, 50 Hz

Capacity

kW

4.85

6.4

7.8

Input

kW

1.48

2.17

2.78

Weight

Indoor

kg

16

Outdoor

kg

38

57

72

Refrigerant fi lling capacity (R410A)

kg

1.20

1.30

1.85

IP code

Indoor

IP 20

Outdoor

IP 24

Permissible excessive  

operating pressure

LP ps

MPa

1.64

HP ps

MPa

4.15

Noise level

Indoor (Super High/

High/Med./Low)

dB(A)

45/42/38/34

48/45/41/37

50/47/43/39

Outdoor

dB(A)

52

54

55

SG79F572H01_en.indd   9

2012/12/19   9:13:21

Summary of Contents for MS-GF50VA

Page 1: ...Για να χρησιμοποιήσετε αυτή τη μονάδα σωστά και με ασφάλεια βεβαι ωθείτε ότι έχετε διαβάσει αυτό το εγχειρίδιο οδηγιών πριν από τη χρή ση LIBRETTO D ISTRUZIONI Per gli utenti Per utilizzare correttamente ed in tutta sicurezza questo apparecchio leggere il presente libretto d istruzioni prima dell uso MANUAL DE INSTRUCCIONES Para los clientes Para utilizar esta unidad de forma correcta y segura lea...

Page 2: ...air conditioner may cause fire electric shock injury or water leakage etc Consult your dealer If the power supply cord is damaged it must be replaced by the manufacturer or its service agent in order to avoid a hazard When installing relocating or servicing the unit make sure that no substance other than the specified refrigerant R410A enters the refrigerant circuit Any presence of foreign substance...

Page 3: ...se injury since the fan inside rotates at high speeds during operation When the unit will be unused for a long time disconnect the power plug or turn the breaker OFF The unit may accumulate dirt which may cause overheating or fire Replace all batteries of the remote controller with new ones of the same type Using an old battery together with a new one may cause overheat ing leakage or explosion If ...

Page 4: ...e 3 RESET button Page 3 Lid Slide down to open Install the remote control ler holder in a place where the signal can be received by the indoor unit Only use the remote controller provided with the unit Do not use other remote controllers If two or more indoor units are installed in proximity to one another an indoor unit that is not intended to be operated may respond to the remote controller Inst...

Page 5: ...ust before the shutoff of the main power When timer is set timer setting is cancelled and the unit starts operation when power is resumed If you do not want to use this function please consult the service repre sentative because the setting of the unit needs to be changed SELECTING OPERATION MODES Set temperature 24 C Fan speed Medium Horizontal vane Auto I FEEL COOL DRY FAN Note The first 30 minut...

Page 6: ...o 1 hour to prevent any condensa tion from dripping Swing The vane moves up and down intermittently AUTO Low Med High Super High AUTO 1 2 3 4 5 SWING SWING OPERATING INSTRUCTIONS FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT LONG OPERATION Press to start LONG operation Fan speed increases and the horizontal vane moves to the position for LONG mode Air reaches to longer distance Press again to cancel ...

Page 7: ...cally set at 2 C higher it is possible to perform cooling operation with keeping comfort As a result energy can be saved TIMER OPERATION ON OFF TIMER 1 Press or during operation to set the timer ON timer The unit turns ON at the set time OFF timer The unit turns OFF at the set time or blinks Make sure that the current time is set correctly Page 3 2 Press Increase and Decrease to set the time of ti...

Page 8: ... also to eliminate bacteria and viruses This air filter has a semi permanent lasting effect even after washing it with water Air cleaning filter Electrostatic anti allergy enzyme filter option Every 3 months Remove dirt by a vacuum cleaner When dirt cannot be removed by vacuum cleaning Soak the filter and its frame in lukewarm water before rinsing it After washing dry it well in shade Every year Repla...

Page 9: ...pe or pipe connecting sections are cooled and this causes water to condense Remote controller The display on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 3 Is the polarity of the batteries correct Page 3 Are any buttons on the remote controller of other electric appliances being pressed Does not co...

Page 10: ...onditioner interferes with radio or TV reception 1 Set to the highest temperature in manual COOL mode and operate for 3 to 4 hours Page 4 This dries the inside of the unit Moisture in the air conditioner contributes to favorable conditions for growth of fungi such as mold 2 Press to stop the operation 3 Turn off the breaker and or disconnect the power sup ply plug 4 Remove all batteries from the r...

Page 11: ...rmepumper ved bruk i boliger samt kommersielle og lettindustrielle miljøer vakuuttaa täten yksinomaisella vastuullaan että jäljempänä kuvatut asuinrakennuksiin pienteollisuuskäyttöön ja kaupalliseen käyttöön tarkoitetut ilmastointilaitteet ja lämpöpumput Note Its serial number is on the nameplate of the product Hinweis Die Seriennummer befindet sich auf dem Kennschild des Produkts Remarque Le numé...

Reviews: