20
9-7. EMERGENCY/TEST OPERATION
In case of test run operation or emergency operation, use
EMERGENCY OPERATION switch on the right side of the indoor unit.
Emergency operation is available when the remote controller is miss-
ing, has failed or the batteries of the remote controller run down. The
unit will start and OPERATION INDICATOR lamp will light.
The first 30 minutes of operation is the test run operation. This opera-
tion is for servicing. The indoor fan runs at High speed and the tem-
perature control does not work.
After 30 minutes of test run operation, the system shifts to
EMERGENCY COOL MODE with a set temperature of 24°C. The fan
speed shifts to Med.
The coil frost prevention works even in the test run or the emergency
operation.
In the test run or emergency operation, the horizontal vane operates in
VANE AUTO ( ) mode.
Emergency operation continues until EMERGENCY OPERATION
switch is pressed again or the unit receives any signal from the remote
controller. In case of latter, normal operation will start.
NOTE:
Do not press EMERGENCY OPERATION switch during normal operation.
Operation mode
COOL
Set temperature
24°C
Fan speed
Med.
Horizontal vane
Auto
The operation mode is indicated by the
Operation Indicator lamp as following
Operation Indicator lamp
EMERGENCY COOL
↓
STOP
Lighted
Not lighted
9-8. 3-MINUTE TIME DELAY OPERATION
When the system turns OFF, compressor will not restart for 3 minutes as 3-minute time delay function operates to protect
compressor from overload.
Emergency
operation switch
(E.O. SW)
OBH621A