8
When the indoor unit is controlled with the remote controller, the operation mode, set temperature, and the fan speed are
memorized by the indoor electronic control P.C.board. The “AUTO RESTART FUNCTION” sets to work the moment
power has restored after power failure. Then, the unit will restart automatically. However if the unit is operated in “I FEEL
CONTROL” mode before power failure, the operation is not memorized. In “I FEEL CONTROL” mode, the operation is
decided by the initial room temperature.
Operation
1
If the main power has been cut, the operation settings remain.
2
After the power is restored, the unit automatically resumes the same operation
as the memory has recorded.
However, it takes the compressor at least 3 minutes to get started.
How to release “AUTO RESTART FUNCTION”
1
Turn off the main power for the unit.
2
Pull out the indoor electronic control P.C. board and the power monitor, receiver
P.C. board. (Refer to 9-1.)
3
Solder the Jumper wire to the JR07 on the indoor electronic control P.C.board.
(Refer to 8-6.)
JR07
IC101
CN151
SW1
CN1
12
CN1
11
CN201
52C
C1
1
CN21
1
CN1V1
CN1R1
CN121
7-3. AUTO RESTART FUNCTION
NOTE:
•
The operation settings are memorized when 10 seconds have passed after the indoor unit was operated with the remote
controller.
•
If the main power is turned off or a power failure occurs while AUTO START/STOP timer is active, the timer setting is
cancelled.
•
If the unit has been off with the remote controller before power failure, the auto restart function does not work as the
power button of the remote controller is off.
•
To prevent breaker off due to the rush of starting current, systematize other home appliances not to turn on at the same
time.
•
When some air conditioners are connected to the same supply system, if they are operated before power failure, the
starting current of all the compressors may flow simultaneously at restart.
Therefore, the special counter-measures are required to prevent the main voltage-drop or the rush of the starting current
by adding to the system that allows the units to start one by one.
No. 1 unit
No. 2 unit
No. 3 unit
No. 4 unit
1 unit operation
No modification
–
–
–
2 units operation
Same as at left
Solder J1
–
–
3 units operation
Same as at left
Same as at left
Solder J2
–
4 units operation
Same as at left
Same as at left
Same as at left
Solder both J1 and J2
Table 1
How to set the remote controller exclusively for particular indoor unit
After you turn the breaker ON, the first remote controller that sends the signal to the indoor unit will be regarded as the
remote controller for the indoor unit.
The indoor unit only accepts the signal from the remote controller that has been assigned to the indoor unit once they are
set.
The setting will be cancelled if the breaker has turned off, or the power supply has shut down.
Please conduct the above setting once again after the power has restored.
OB396--1.qxp 05.3.18 8:59 AM Page 8
Summary of Contents for MS-A08ND
Page 23: ...23 ...