3. Operation
3.6. 3D i-see Sensor setting
Note:
This function cannot be set depending on the outdoor unit to be
connected.
3.6.1 3D i-see Sensor setting
Operation
Main
Main menu
F1
F2
F3
F4
Cursor
Operation
Vane·Louver·Vent. (Lossnay)
High power
Comfort
Main menu:
F1
F2
F3
F4
Comfort
Cursor
Manual vane angle
3D i-See sensor
Setting display:
F1
F2
F3
F4
3D i-See sensor
Cursor
Setting display:
Air distribution
Energy saving option
Seasonal airflow
F1
F2
F3
F4
3.6.2 Air distribution
Air distribution
Input display:
Cur.
Address
Check
Ref. address
Unit No.
Identify unit Check button
F1
F2
F3
F4
Air distribution
Select:
Cur.
Ref. address
Unit No.
Auto vane
Direct/Indirect setting
All
Direct/Indirect
F1
F2
F3
F4
Direct/Indirect setting
: Direct
: Indirect
: Indirect
: Direct
Select:
Outlet
Angle
F1
F2
F3
F4
■
i-see button (Wireless remote controller)
1
Each time
is pressed during operation, the setting changes in
the following order: OFF
→
Direct
→
Indirect.
Display
Setting
OFF
Direct
Indirect
When the setting is changed from OFF to Direct or Indirect, the vane
setting changes to “Auto”. This setting is applied collectively to all of the
vanes.
1
Select “Operation” from the Main
menu, and press the [SELECT]
button.
2
Select “Comfort” from the
Operation menu, and press the
[SELECT] button.
3
Select “3D i-See sensor” with the
[F1] or [F2] button, and press the
[SELECT] button.
4
Select the desired menu with the
[F1] or [F2] button, and press the
[SELECT] button.
• Air distribution
Select the air
fl
ow direction
control method when the air
fl
ow
direction is set to “Auto”.
• Energy saving option
Operates the energy-save mode
according to whether persons are
detected in the room by the 3D
i-see Sensor.
• Seasonal air
fl
ow
When the thermostat turns off,
the fan and the vanes operate
according to the control settings.
1
Move the cursor to “Ref. address”
or “Unit No.” with the [F1] button
to select.
Select the refrigerant address
and the unit number for the units
to whose vanes are to be
fi
xed,
with the [F2] or [F3] button, and
press the [SELECT] button.
• Ref. address: Refrigerant address
• Unit No.: 1, 2, 3, 4
Press the [F4] button to con
fi
rm
the unit.
The vane of only the target
indoor unit is pointing downward.
2
Select the menu with the [F4]
button.
Default
→
Area
→
Direct/Indirect
→
Default…
Default: The vanes move the
same as during normal operation.
“Area”*: The vanes move to the
down air
fl
ow direction toward ar-
eas with a high
fl
oor temperature
during cooling mode and toward
areas with a low
fl
oor tem-
perature during heating mode.
Otherwise, the vanes move to the
horizontal air
fl
ow direction.
“Direct/Indirect”*:
The
vanes
automatically move relative to
the areas where persons are
detected.
The vanes operate as indicated
in the following table.
* In order to enable this function,
the air
fl
ow direction must be set
to “Auto”.
3
When Direct/Indirect is selected,
set each air outlet.
Select the air outlet with the
[F1] or [F2] button, and change
the setting with the [F4] button.
After changing the settings for
all of the air outlets, press the
[SELECT] button to save the set-
tings.
Vane setting
Direct
Indirect
Cooling
horizontal
→
swing
keep horizontal
Heating
keep downward
downward
→
horizontal