DImENSIoNS: SEZ-KD18NA
Unit : mm(in.)
(46-7/8)
1190
(39)
990
(31-1/8)
790
N
(48-25/32)
1239
(40-29/32)
1039
(33-1/16)
839
M
Drain pipe(O.D.ø32(1-1/4))
Terminal block (Remote controller transmission line)
Terminal block (Indoor/outdoor connecting line)
2
Refrigerant piping
flare connection (liquid)
ø12.7(1/2)
mm(in.)
(35-7/16)
(27-9/16)
(19-11/16)
(41-3/4)
(33-7/8)
(26)
(47-1/4)
(39-3/8)
(31-1/2)
(39-3/8)
(31-1/2)
(23-5/8)
(41-3/4)
(33-7/8)
(26)
(47-3/16)
(39-5/16)
(31-7/16)
(45-3/8)
(37-1/2)
(29-5/8)
(43-5/16)
(35-7/16)
(27-9/16)
700
Drain pipe(O.D.ø32(1-1/4))
(Emergency draining)
ø6.35(1/4)
ø9.52(3/8)
SEZ-KD15NA
900
952
998
860
9
800 1000
860
7
700
20
24
16
L
900
500
K
9
5
J
1060
660
H
800
600
7
660
798
752
Knockout hole ø27(1-3/32)
(Remote controller transmission line)
Knockout hole ø27(1-3/32)
(Indoor/outdoor connecting line)
G
1200
F
1000
E
11
D
1060
C
1100
B
1152
SEZ-KD09NA
SEZ-KD12NA
SEZ-KD18NA
Model
A
1198
Gas pipe
Liquid pipe
L-ø2.9(1/8)
2X2-ø2.9(1/8)
2XE-ø2.9(1/8)
Control box
Air filter
Suspension bolt hole
4-14X30(9/16X1-3/16) Slot
Refrigerant piping
flare connection (gas)
1
1
2
Drain pipe(O.D.ø32(1-1/4))
(Spontaneous draining)
Air
inlet
Air
outlet
N
M
175
±
5(6-29/32
±
7/32)
Less than 300
Less than 550
(11-13/16)
(21-21/32)
More than 20
More than 10
57
(2-1/4)
57
(2-1/4)
(1-31/32 ~ 5-29/32)
(30-19/32)
(17-23/32)
(11-13/16)
(17-23/32)
More than 300
(13/16)
(13/32)
(3-9/16)
(5-29/32)
(2-25/32)
(4-19/32)
70
10(13/32)
(3-15/16)
(1-15/16)
(24-5/8)
450
37(1-15/32)
200(7-7/8)
H
157.5(6-7/32)
20(13/16)
100(3-15/16)
37(1-15/32)
12(1/2)
12
(1/2)
88
(3-15/32)
100(3-15/16)XJ=
K
100
(3-15/16)
88
(3-15/32)
777
50(1-31/32)
50 ~ 150
50(1-31/32)
G
450
10(13/32)
49
25
(1)
170
(6-23/32)
102
(4-1/32)
116
100
25
(1)
23(29/32)
C
B (Suspension bolt pitch)
23
(29/32)
A
90
D (Duct)
100(3-15/16)X(E-1)=
F
100
(3-15/16)
15(19/32)
Drain hose (I.D.ø32(1-1/4))
<accessory>
(Actual length)
Note2
Access door
Required space for service and maintenance
Access door
Ceiling surface
Make the access door at the appointed position properly
for service maintenance.
Note1.Use M10 screw for the suspension bolt (field supply).
2.Keep the service space for the maintenance at the bottom.
3.This chart indicates for SEZ-KD15NA model,which has 3 fans.
SEZ-KD09,12NA models have 2 fans.
SEZ-KD18NA models have 4 fans.
4.In case an inlet duct is used,remove the air filter(supply with
the unit), then install the filter(field supply) at suction side.
159(6-9/32)
345(13-19/32)
20(13/16)
30(1-3/16)
23(29/32)
270(10-21/32)
20(13/16)
625(Suspension bolt pitch)
700(27-9/16)
677(26-21/32)
150(Duct)