3400 Lawrenceville Suwanee Rd

Suwanee, GA 30024

Tele: 678-376-2900 • Fax: 800-889-9904

Toll Free: 800-433-4822 (#3)

www.mehvac.com

Specifications are subject to change without notice.

C SD - SEZ-KD18NA - 200903   © MITSUBISHI ELECTRIC / HVAC 2009

DImENSIoNS: SEZ-KD18NA

 

Unit : mm(in.)

(46-7/8)

1190

(39)

990

(31-1/8)

790

N

(48-25/32)

1239

(40-29/32)

1039

(33-1/16)

839

M

Drain pipe(O.D.ø32(1-1/4))

 Terminal block (Remote controller transmission line)

 Terminal block (Indoor/outdoor connecting line)

2

Refrigerant piping
flare connection (liquid)

ø12.7(1/2)

mm(in.)

(35-7/16)

(27-9/16)

(19-11/16)

(41-3/4)

(33-7/8)

(26)

(47-1/4)

(39-3/8)

(31-1/2)

(39-3/8)

(31-1/2)

(23-5/8)

(41-3/4)

(33-7/8)

(26)

(47-3/16)

(39-5/16)

(31-7/16)

(45-3/8)

(37-1/2)

(29-5/8)

(43-5/16)

(35-7/16)

(27-9/16)

700

Drain pipe(O.D.ø32(1-1/4))
(Emergency draining)

ø6.35(1/4)

ø9.52(3/8)

SEZ-KD15NA

900

952

998

860

9

800 1000

860

7

700

20

24

16

L

900

500

K

9

5

J

1060

660

H

800

600

7

660

798

752

 Knockout hole ø27(1-3/32)
 (Remote controller transmission line)

 Knockout hole ø27(1-3/32)
 (Indoor/outdoor connecting line)

G

1200

F

1000

E

11

D

1060

C

1100

B

1152

SEZ-KD09NA

SEZ-KD12NA

SEZ-KD18NA

Model

A

1198

Gas pipe

Liquid pipe

L-ø2.9(1/8)

2X2-ø2.9(1/8)

2XE-ø2.9(1/8)

Control box

Air filter

Suspension bolt hole
4-14X30(9/16X1-3/16) Slot

Refrigerant piping

flare connection (gas)

1

1

2

 Drain pipe(O.D.ø32(1-1/4))

(Spontaneous draining)

Air

inlet

Air

outlet

N

M

175

±

5(6-29/32

±

7/32)

Less than 300

Less than 550

(11-13/16)

(21-21/32)

More than 20

More than 10

57

(2-1/4)

57

(2-1/4)

(1-31/32 ~ 5-29/32)

(30-19/32)

(17-23/32)

(11-13/16)

(17-23/32)

More than 300

(13/16)

(13/32)

(3-9/16)

(5-29/32)

(2-25/32)

(4-19/32)

70

10(13/32)

(3-15/16)

(1-15/16)

(24-5/8)

450

37(1-15/32)

200(7-7/8)

H

157.5(6-7/32)

20(13/16)

100(3-15/16)

37(1-15/32)

12(1/2)

12

(1/2)

88

(3-15/32)

100(3-15/16)XJ=

K

100

(3-15/16)

88

(3-15/32)

777

50(1-31/32)

50 ~ 150

50(1-31/32)

G

450

10(13/32)

49

25

(1)

170

(6-23/32)

102

(4-1/32)

116

100

25

(1)

23(29/32)

C

B (Suspension bolt pitch)

23

(29/32)

A

90

D (Duct)

100(3-15/16)X(E-1)=

F

100

(3-15/16)

15(19/32)

Drain hose (I.D.ø32(1-1/4))

<accessory>

(Actual length)

Note2

Access door

Required space for service and maintenance

Access door

Ceiling surface

Make the access door at the appointed position properly
for service maintenance.

Note1.Use M10 screw for the suspension bolt (field supply).

    2.Keep the service space for the maintenance at the bottom.

    3.This chart indicates for SEZ-KD15NA model,which has 3 fans.

      SEZ-KD09,12NA models have 2 fans.

      SEZ-KD18NA models have 4 fans.

    4.In case an inlet duct is used,remove the air filter(supply with

      the unit), then install the filter(field supply) at suction side.

159(6-9/32)

345(13-19/32)

20(13/16)

30(1-3/16)

23(29/32)

270(10-21/32)

20(13/16)

625(Suspension bolt pitch)

700(27-9/16)

677(26-21/32)

150(Duct)