SPECIFICATIONS
Cooling
22,200
6,500
2.72
0.09
0.43
0.80
11.78 / 4.11
Heating
25,200(32,400)
7,400(9,500)
2.67(4.77)
0.09<2.10>
0.43<8.75>
0.80<8.75>
11.55 / 4.03
PKH-P2.5FALH / PKH-P2.5FALH
1
PKA-P2.5FAL / PKA-P2.5FAL
1
Single phase, 50Hz, 220-230-240V
Munsell 3.4Y 7.7/0.8
Plate fin coil
Line flow (direct) x 2
0.040
15-20 (530-706)
0(direct blow)
<2.1>
Wireless remote controller & built-in
39-45
20(13/16)
1,400(13/16)
235(9-1/4)
340(13-3/8)
26(57)
24(53)
PUH-P2.5VGA, PUH-P2.5VGA
1
/ PUH-P2.5YGA, PUH-P2.5YGA
1
Single phase, 50Hz, 220-230-240V / 3 phase, 50Hz, 380-400-415V(4wires)
77 / 32
Munsell 5Y 7/1
Linear Expansion Valve
Hermetic
NE41VMJM / NE41YEJM
1.9
Line start
Internal thermostat, HP switch, Discharge thermo. / Thermal relay, Discharge thermo, HP switch, Anti-phase protector.
38
Plate fin coil
Propeller (direct) x 1
0.070
50(1,770)
Reverse cycle
48
50
900(35-7/16)
330+20(13+3/4)
855 (33-5/8)
82(181)
R407C
3.3(7.3)
1.2 (Ester)MEL56
9.52 (3/8)
15.88 (5/8)
Flared
Flared
Max. 50m
Max. 50m
PKH-P2.5FALH / PKH-P2.5FALH
1
PKA-P2.5FAL / PKA-P2.5FAL
1
Service Ref. With Electric heater
Without Electric heater
With Electric heater
Without Electric heater
With Electric heater
Without Electric heater
Item
Btu/h
W
kW
kW
A
A
kW
K
/min(CFM)
Pa(mmAq)
kW
dB
mm(in.)
mm(in.)
mm(in.)
mm(in.)
kg(lbs)
kg(lbs)
A
A
kW
W
kW
K
/min(CFM)
dB
dB
mm(in.)
mm(in.)
mm(in.)
kg(lbs)
kg(lbs)
L
mm(in.)
mm(in.)
Function
Capacity
w
1
Total input
w
1
Service Ref.
Power supply(phase, cycle,voltage)
Input
w
2
Running current
w
2
Starting current
w
2
External finish
Heat exchanger
Fan
Fan(drive) x No.
Fan motor output
Airflow(Low-High)
External static pressure
Booster heater
w
2
Operation control & Thermostat
Noise level(Low-High)
Unit drain pipe O.D.
Dimensions
Weight
Service Ref.
Power supply (phase, cycle, voltage)
Running current
Starting current
External finish
Refrigerant control
Compressor
Model
Motor output
Starter type
Protection devices
Crankcase heater
Heat exchanger
Fan
Fan(drive) x No.
Fan motor output
Airflow
Defrost method
Noise level
Dimensions
Weight
Refrigerant
Charge
Oil (Model)
Pipe size O.D.
Connection method
Between the indoor &
outdoor unit
INDOOR UNIT
OUTDOOR UNIT
REFRIGERANT PIPING
W
D
H
Cooling
Heating
W
D
H
Liquid
Gas
Indoor side
Outdoor side
Height difference
Piping length
Notes1. Rating Conditions (ISO T1)
Cooling : Indoor : D.B. 27˚C(80˚F), W.B. 19˚C (66˚F)
Outdoor
: D.B. 35˚C(95˚F), W.B. 24˚C (75˚F)
Heating : Indoor : D.B. 20˚C(68˚F)
Outdoor
: D.B. 7˚C(45˚F), W.B. 6˚C (43˚F)
Refrigerant piping length (one way) : 5m (16ft)
3. Above data based on indicated voltage
Indoor Unit Single phase 240V 50Hz
Outdoor Unit Single phase 240V 50Hz / 3 phase 415V 50Hz
2. Guaranteed operating range
Upper limit
Lower limit
Upper limit
Lower limit
Indoor
D.B. 35˚C, W.B. 22.5˚C
D.B. 19˚C, W.B. 15˚C
D.B. 28˚C
D.B. 17˚C
Outdoor
D.B. 46˚C
D.B. -5˚C
D.B. 24˚C, W.B. 18˚C
D.B. -11˚C, W.B. -12˚C
Cooling
Heating
w
1 : ( ) Shows the total rating.
w
2 : < > Shows the only booster heater rating.
1. Heat pump type
OC175B--1.qxp 01.10.2 3:11 PM Page 7