Mitsubishi Electric Mr.SLIM PCA-RP KAQ Operation Manual Download Page 8

8

C

C

TIME SUN

WEEKLY

10

C

TIMER

SUN

ON

OFF

WEEKLY

8

9

1

Timer Settings

1.  Be sure that the weekly timer indicator is visible on the screen (at 

 

).

2.  Press the Timer Menu button 

  so that “Monitor” is indicated on the 

screen (at 

).

3.  Press the Timer On/Off (Set Day) button 

 as necessary to select the 

day you wish to view.

4.  Press the 

 or 

 Operation button ( 

 or 

 ) as necessary to change 

the timer operation shown on the display (at 

).

 *  

Each press will advance to the next timer operation, in order of time 
setting.

5.  To close the monitor and return to the standard control screen, press 

the Mode (Return) button 

.

<To Turn Off the Weekly Timer>

Press the Timer On/Off button 

 so that “Timer Off” appears at 

10

.

Note:
By setting the day to “Sun Mon Tues Wed Thurs Fri Sat”, you can set the 
same operation to be carried out at the same time every day.
(Example: Operation 2 above, which is the same for all days of the week.)

Setup Matrix

Op No.

Sunday

Monday

...

Saturday

No. 1

• 8:30
• ON
• 23 

°C

No. 2

• 10:00
• OFF

• 10:00
• OFF

• 10:00
• OFF

• 10:00
• OFF

...

No. 8

<Operation 1 settings for Sunday>
Start the air conditioner at 8:30, with 
the temperature set to 23 °C.

<Operation 2 settings for every day>
Turn off the air conditioner at 10:00.

5.  Press the appropriate Set Time button 

 

 as necessary to set the de-

sired time (at 

).

 *  

As you hold the button down, the time first increments in minute in-
tervals, then in 10-minute intervals, and then in 1-hour intervals.

6.  Press the ON/OFF button 

  to select the desired operation (ON or 

OFF), at 

.

 *  

Each press changes the next setting, in the following sequence: No 
display (no setting) → “ON” → “OFF”

7.  Press the appropriate Set Temperature button 

 to set the desired 

temperature (at 

).

 *  

Each press changes the setting, in the following sequence: No dis-
play (no setting) 

 24 

 25 

 ... 

 29 

 30 

12 

 ... 

 23 

 No display.

     (Available range: The range for the setting is 12 °C to 30 °C. The 

actual range over which the temperature can be controlled, how-
ever, will vary according to the type of the connected unit.)

8.  After making the appropriate settings at Steps 5, 6 and 7, press the 

Filter   button 

 to lock in the values.

   To clear the currently set values for the selected operation, press and 

quickly release the Check (Clear) button 

 once.

 *  

The displayed time setting will change to “—:—”, and the On/Off 
and temperature settings will all disappear.

     (To clear all weekly timer settings at once, hold down the Check 

(Clear) button 

 for 2 seconds or more. The display will begin blink-

ing, indicating that all settings have been cleared.)

 Note:

 

 Your new entries will be cancelled if you press the Mode (Return) button 

  

 

before pressing the Filter   butto

.

 

 If you have set 2 or more different operations for exactly the same time, 
only the operation with the highest Operation No. will be carried out.

9.  Repeat Steps 3 to 8 as necessary to fill as many of the available cells 

as you wish.

10. Press the mode (Return) button 

 to return to the standard control 

screen and complete the setting procedure.

11. To activate the timer, press the Timer On/Off button 

, so that the 

“Timer Off” indication disappears from the screen. 

Be sure that the 

“Timer Off” indication is no longer displayed.

 *  

If there are no timer settings, the “Timer Off” indication will blink on 
the screen.

<Setting the Weekly Timer>

C

SUN

ON

WEEKLY

Shows the selected operation (ON or OFF)
*  Does not appear if operation is not set.

Shows the temperature setting
*  

Does not appear if temperature 
is not set.

Shows the time 
setting

<How to View the Weekly Timer Settings>

C

C

TIME SUN

WEEKLY

10

6.1.2. Simple Timer

 

You can set the simple timer in any of 3 ways.

 •  

Start time only:

    The air conditioner starts when the set time has elapsed.
 •  

Stop time only:

    The air conditioner stops when the set time has elapsed.
 •  

Start & stop times:

    The air conditioner starts and stops at the respective elapsed times.

 

The simple timer (start and stop) can be set only once within a 72-hour 
period.

  The time setting is made in hour increments.

Note:
*1.  

Weekly Timer/Simple Timer/Auto Off Timer cannot be used at the same 
time.

*2.  

The simple timer will not operate when any of the following conditions 
is in effect.

 

 

 The timer is off; the system is in malfunction state; a test run is in prog-
ress; the remote controller is undergoing self-check or remote control-
ler check; the user is in the process of selecting a function; the user is 
in the process of setting the timer; the system is under central control. 
(Under these conditions, On/Off operation is prohibited.)

ON

Hr

AFTER

SIMPLE

PAR-21MAA

ON/OFF

FILTER

CHECK

OPERATION

CLEAR

TEST

TEMP.

MENU

BACK

DAY

MONITOR/SET

CLOCK

ON/OFF

<To Turn On the Weekly Timer>

Press the Timer On/Off button 

 so that the “Timer Off” indication (at 

10

)

goes dark.

 

6. Timer

3.  Press the Timer On/Off (Set Day) button 

 to set the day. Each press 

advances the display at 

 to the next setting, in the following se-

quence: “Sun Mon Tues Wed Thurs Fri Sat” → “Sun” → ... → “Fri” → 
“Sat” → “Sun Mon Tues Wed Thurs Fri Sat”...

4.  Press the 

 or 

 Operation button (

 or 

) as necessary to select 

the appropriate operation number (1 to 8) 

.

 *  

Your inputs at Steps 3 and 4 will select one of the cells from the ma-
trix illustrated below. 

     (The remote-controller display at left shows how the display would 

appear when setting Operation 1 for Sunday to the values indicated 
below.)

2.  Press the Timer Menu button 

, so that the “Set Up” appears on the 

screen (at 

). (Note that each press of the button toggles the display 

between “Set Up” and “Monitor”.)

Summary of Contents for Mr.SLIM PCA-RP KAQ

Page 1: ...o correctas leia atentamente o manual de operação antes de pôr a funcionar a unidade de ar condicionado DRIFTSMANUAL Læs venligst denne driftsmanual grundigt før airconditionanlægget betjenes af hensyn til sikker og korrekt brug DRIFTSMANUAL Läs denna driftsmanual noga för säkert och korrekt bruk innan luftkonditioneringen används Français Deutsch English Nederlands Español Italiano Português Dans...

Page 2: ... for EU countries only This symbol mark is according to the directive 2002 96 EC Article 10 Information for users and Annex IV and or to the directive 2006 66 EC Article 20 Information for end users and Annex II Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and or reused This symbol means that electrical and electroni...

Page 3: ... The indicator shows the direc tion of the outcoming airflow Day of Week Shows the current day of the week Room Temperature display Shows the room temperature The room temperature display range is 8 39 C The display blinks if the temperature is less than 8 C or 39 C or more Time Timer Display Shows the current time unless the simple or Auto Off timer is set If the simple or Auto Off timer is set sh...

Page 4: ...ndoor Outdoor Connection wire Ref Pipes Indoor Unit PSA RP KA Fan speed 3 speeds Auto Vane Manual Louver Auto with swing Filter Long life Filter cleaning indication 2 500 hr PSA RP KA Floor Standing Air intake Filter Air outlet Vane Louver Remote controller ...

Page 5: ...ton as necessary to set the time As you hold the button down the time at will increment first in one minute intervals then in ten minute intervals and then in 1 hour intervals 4 After making the appropriate settings at Steps 2 and 3 press the Filter button to lock in the values 5 Operation F C TIMER MON OFF WEEKLY SUN MON TUE WED THU FRI SAT WEEKLY F C C TIME SUN Function Selection of remote contro...

Page 6: ...inutes the air conditioner switches to cooling mode In the same way if the room temperature remains 2 C or more below the set temperature for 15 minutes the air conditioner switches to heating mode Because the room temperature is automatically adjusted in order to maintain a fixed effective temperature cooling operation is performed a few degrees warmer and heating operation is performed a few de g...

Page 7: ...ing operation the arrow display move to the left and right Low High 6 Timer 6 1 For Wired Remote controller You can use Function Selection of remote controller to select which of 3 types of timer to use Weekly timer Simple timer or Auto Off timer 6 1 1 Weekly Timer The weekly timer can be used to set up to 8 operations for each day of the week Each operation may consist of any of the following ON ...

Page 8: ...you have set 2 or more different operations for exactly the same time only the operation with the highest Operation No will be carried out 9 Repeat Steps 3 to 8 as necessary to fill as many of the available cells as you wish 10 Press the mode Return button to return to the standard control screen and complete the setting procedure 11 To activate the timer press the Timer On Off button so that the T...

Page 9: ... OFF indication appears at ON timer The air conditioner will start operation when the specified number of hours has elapsed OFF timer The air conditioner will stop operation when the specified number of hours has elapsed Timer Setting TIMER ON OFF Hr AFTER SIMPLE C C SIMPLE 1 Be sure that the simple timer indicator is visible on the screen at 2 Press the Timer Menu button so that the Monitor appears...

Page 10: ...of the following conditions is in effect The timer is off the system is in malfunction state a test run is in prog ress the remote controller is undergoing self check or remote control ler check the user is in the process of selecting a function the user is in the process of setting the timer the system is under central control Under these conditions On Off operation is prohibited AFTER OFF AUTO O...

Page 11: ...s as described above C C TIME SUN FUNCTION ON OFF TEMP CLEAR If you press a locked button the Locked indication at will blink on the display C C FUNCTION C C FUNCTION C C If only the error code is blinking while the ON lamp remains lit Operation is continuing but there may be a problem with the system In this case you should note down the error code and then call your dealer or servicer for advice...

Page 12: ...imum minimum 3 Mode selection MODE SELEC TION 1 Remote controller main sub setting CONTROLLER MAIN SUB Selecting main or sub remote controller When 2 remote controllers are connected to 1 group 1 controller must be set to sub 2 Use of clock setting CLOCK Setting the use or non use of clock function 3 Timer function setting WEEKLY TIMER Setting the timer type 4 Contact number setting for error situ...

Page 13: ...de is displayed when the operation mode is selected Initial setting value The automatic mode is not displayed when the operation mode is selected The temperature range limit is not active Initial setting value The temperature range can be changed on cooling dry mode The temperature range can be changed on heating mode The temperature range can be changed on automatic mode The remote controller wil...

Page 14: ...the lower limit setting press the button The selected setting will blink and the tem perature can be set Settable range Cooling Dry mode Lower limit 19 C 30 C Upper limit 30 C 19 C Heating mode Lower limit 17 C 28 C Upper limit 28 C 17 C Automatic mode Lower limit 19 C 28 C Upper limit 28 C 19 C 8 Function Selection 4 3 Mode selection setting 1 Remote controller main sub setting To switch the sett...

Page 15: ...ture cooling day mode Limit temperature heating mode Limit temperature auto mode Mode selection Remote controller setting MAIN Remote controller setting SUB Use of clock setting Setting the day of the week and time Timer set Timer monitor Weekly timer Timer mode off Auto off timer Simple timer Contact number setting of error situation Display change Temperature display C F setting Room air tempera...

Page 16: ...u do not have a vacuum clean er tap the filters against a solid object to knock off dirt and dust If the filters are especially dirty wash them in lukewarm water Take care to rinse off any detergent thoroughly and allow the filters to dry completely before putting them back into the unit Caution Do not dry the filters in direct sunlight or by using a heat source such as an electric heater this may war...

Page 17: ...condition may occur when operation starts During defrosting mode cool airflow may blow down and appear like a mist Water or vapor is emitted from the outdoor unit During cooling mode water may form and drip from the cool pipes and joints During heating mode water may form and drip from the heat exchang er During defrosting mode water on the heat exchanger evaporates and water vapor may be emitted T...

Page 18: ...lose The batteries are low Replace the batteries and press the Reset button If nothing appears even after the batteries are replaced make sure that the batteries are installed in the correct directions The operation lamp near the receiver for the wireless remote controller on the indoor unit is blinking The self diagnosis function has operated to protect the air conditioner Do not attempt to repai...

Page 19: ...inted in PRC RG79D719H04 HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Please be sure to put the contact address telephone number on this manual before handing it to the customer ...