37
PLA-RP100AA2 PLA-RP125AA2 PLA-RP140AA2
INDOOR POWER BOARD
[LEGEND]
P.B
INDOOR CONTROLLER BOARD
I.B
CN2L
CONNECTOR(LOSSNAY)
CN32
CONNECTOR(REMOTE SWITCH)
CN41
CONNECTOR(HA TERMINAL-A)
CN51
CONNECTOR(CENTRALLY CONTROL)
SW1
SWITCH(MODEL SELECTION)
w
See table 1
SWITCH(CAPACITY CORD)
w
See table 2
SW2
SWE
CONNECTOR(EMERGENCY OPERATION)
X1
RELAY(DRAIN PUMP)
LED1
POWER SUPPLY(I.B)
LED2
POWER SUPPLY(I.B)
LED3
TRANSMISSION(INDOOR-OUTDOOR)
FUSE
FUSE(T5AL250V)
ZNR
VARISTOR
IPM
POWER MODULE
SYMBOL
NAME
SYMBOL
NAME
SYMBOL
NAME
MF
FAN MOTOR
MV VANE
MOTOR
DP
DRAIN-UP MACHINE
DS
DRAIN SENSOR
DCL
REACTOR
H2
DEW PREVENTION HEATER
TB2
TERMINAL BLOCK (Indoor unit Power (option))
TB4
TERMINAL BLOCK
(INDOOR/OUTDOOR CONNECTING LINE)
TB5, TB6
TERMINAL BLOCK(REMOTE
CONTROLLER TRANSMISSION LINE)
TH1
ROOM TEMP.THERMISTOR
(0
:
/15k
"
,25
:
/5.4k
"
DETECT)
TH2
PIPE TEMP.THERMISTOR/LIQUID
(0
:
/15k
"
,25
:
/5.4k
"
DETECT)
TH5
COND./EVA. TEMP. THERMISTOR
(0
:
/15k
"
,25
:
/5.4k
"
DETECT)
R.B
WIRED REMOTE CONTROLLER BOARD
W.B
WIRELESS REMOTE CONTROLLER BOARD
RU
RECEIVING UNIT
BZ
BUZZER
LED1
LED(RUN INDICATOR)
LED2
LED(HOT ADJUST)
SW1
SWITCH(HEATING ON/OFF)
SW2
SWITCH(COOLING ON/OFF)
Please set the voltage using the
remote controller.
For the setting method. please refer to
the indoor unit Installation Manual.
S1
S2
S3
TB4
TO
OUTDOOR
UNIT
YLW
ORN
YLW
YLW
ORN
BRN
ORN
1
1
1
3
1
2
2
5
1
2
3
1
3
5
5
3
RECTIFIER
TRANS
IPM
P.B
MF
1
2
3
9 5 10
7
6
3
2
1
8
4
5
MV
5
MV
5
5
MV
5
MV
GRILLE
H2
GRILLE
BLK
X1
J41
J42
X1
3
1
2
1
3
DP
D.U.M
CNP
(BLU)
YLW
YLW
ORN
ORN
YLW
BLK
WHT
PNK
3
1
3
3
1
3
1
YLW
YLW
D.HEATER
CNC
(RED)
CN33
(GRN)
CN02
(GRN)
CN01
(BLK)
POSITION DETECTION
SENSOR INPUT
CN3
(WHT)
CN03
(BLU)
CN2S
(WHT)
FAN
CN2
(GRN)
CN4
(WHT)
FUSE
ZNR
DCL
FAN
WHT
BRN
POWER
CND
(ORN)
2
1
POWER
CN2D
(WHT)
INDOOR/OUTDOOR
COMMUNICATION
CN3C
(BLU)
CN41
CN51
CN2L
CN32
9
WIRELESS
CN90
(WHT)
BZ
5
5
VANE
CN6V
(GRN)
W.B
I.B
LED2
CNB
LED1
SW1
SW2
RU
2
1
2
2
1
1
REMOCON
CN22
(BLU)
TB5
TRANSMISSION WIRES
DC12V
TB6
R.B
BLU
BLU
2
1
2
1
2
1
D.SENSOR
CN31
(WHT)
INTAKE
CN20
(RED)
LIQUID
CN21
(WHT)
DS
TH2
2
1
PIPE
CN29
(BLK)
TH5
TH1
LED3
Pair No.
LED2 LED1
ON
OFF
SWE
Refer to tables 1
and 2.
w
Be sure to turn off the source power
and then disconnect fan motor connector.
(Failure to do so will cause trouble in Fan motor)
SW2
SW1
BLK
WHT
RED
3
1
INDOOR/OUTDOOR
COMMUNICATION
CN3C
(BLU)
TB4
YLW
ORN
ORN
BRN
TO OUTDOOR UNIT
S1
S2
S3
I.B
P.B
TB2
POWER SUPPLY
~(1PHASE)
230V 50Hz
RED
BLU
GRN/YLW
L
N
3
1
5
CN01
(BLK)
YLW
ORN
w
1 (Fig.1)
1 2 3 4 5
ON
OFF
(Table 1) SW1 (MODEL SELECTION)
SW1
Manufacture/Service
(Table 2) SW2 (CAPACITY CORD)
1 2 3 4 5
ON
OFF
MODELS
SW2
Manufacture/Service
PLA-RP100AA2
PLA-RP140AA2
PLA-RP125AA2
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
MODELS
Manufacture/Service
1.Symbols used in wiring diagram above are, : Connector, :
Terminal (block).
2.Indoor and outdoor connecting wires are made with polarities, make wiring
matching terminal numbers (S1,S2,S3).
3.Since the outdoor side electric wiring may change be sure to check the
outdoor unit electric wiring for servicing.
4.This dlagram shows the wiring of indoor and outdoor connecting wires.
(specification of 230V), adopting superimposed system of power and signal.
w
1 ; When work to supply power separately to indoor and outdoor unit was
applied, refer to Fig1.
w
2 ; For power supply system of this unit, refer to the caution label located
near this diagram.
NOTES:
OCS07-2.qxp 06.3.22 3:40 PM Page 37
Summary of Contents for Mr.Slim PCA-RP GA
Page 34: ...34 WIRED REMOTE CONTROLLER Unit mm 130 120 19 ...
Page 35: ...35 WIRELESS REMOTE CONTROLLER Unit mm 159 3 55 58 19 ...
Page 57: ...57 9 2 PLA RP AA PLA RP AA2 9 2 1 FRESH AIR INTAKE AMOUNT ...
Page 58: ...58 9 2 2 BRANCH DUCT Installation at site ...
Page 68: ...68 PEAD RP60GA PEAD RP71GA ...
Page 69: ...69 PEAD RP100GA ...
Page 74: ...74 ...