13-1.MAJOR SYSTEM CONTROL
13-2.OTHERS
2-remote Controller
Control
With two remote controllers, control
can be performed locally and
remotely from two locations.
Operation Control by
Level Signal
Air conditioner can be started/
stopped remotely. In addition,
On/Off operation by local remote
controller can be prohibited/permitted.
Operation Control by
Pulse Signal
Remote Display of
Operating Status
Operating status can be
displayed at a remote location.
Allows On/Off operation with
timer
*For control by an external
timer, refer to B Operation
Control by Level Signal.
Timer Operation
PAR-21/31MAAU
PAC-YT53CRAU
PAR-21/31MAAU
PAC-YT53CRAU
(Example of 1 : 1 system)
(Example of 1 : 1 system)
Relay box (to be purchased) locally)
Relay box (to be purchased) locally)
Adapter for
remote
On/Off
Adapter for
remote
On/Off
PAR-FL32MA
PAR-FL32MA
(Example of 1 : 1 system)
PAR-21/31MAAU
(Example of 1 : 1 system x 2)
Relay box (to be purchased locally)
(Example of 1 : 1 system x 2)
* Set "Main" and "Sub"
remote controllers.
* When using wired and
wireless remote controllers
PAR-FL32MA
(Example of Simultaneous Twin)
(Example of Simultaneous Twin)
• Wired Remote Controller
PAR-21/31MAAU
PAC-YT53CRAU
• Wireless Remote Controller
PAR-FL32MA
• Wireless Remote Controller Kit for PCA
PAR-SL93B-E
• Adapter for remote On/Off
PAC-SE55RA-E
• Relay box (to be purchased locally)
• Remote control panel (to be purchased
locally)
Standard functions of
PAR-21/31MAAU
A
B
C
D
E
Details
Major Optional Parts Required
System Examples
Wired remote controller
Wireless remote controller
Remote
display
panel
Remote
display
panel
PAR-21/31MAAU/PAC-YT53CRAU
Remote
control
panel
Remote
control
panel
Wired remote
controller
• Up to two remote controllers can be
connected to one group.
• Both wired and wireless remote controllers
can be used in combination.
• Operation other than On/Off (e.g., adjust-
ment of temperature, fan speed, and airflow)
can be performed even when remote
controller operation is prohibited.
• Timer control is possible with an external
timer.
Connector
cable for
remote
display
Connector
cable for
remote
display
PAR-FL32MA
(Example of 1 : 1 system x 2)
Relay box (to be purchased locally)
(Example of 1 : 1 system x 2)
• Connector cable for remote display
PAC-SA88HA-E / PAC-725AD
(10 pcs. x PAC-SA88HA-E)
• Relay box (to be purchased locally)
• Remote control panel (to be purchased
locally)
Remote
control
panel
Remote
control
panel
Wired remote
controller
• The pulse signal can be turned On/Off.
• Operation/emergency signal can be
received at a remote location.
• Operation/emergency signal can be
received at a remote location (when
channeled through the
PAC-SF40RM-E
no-voltage signal, when channeled through
the
PAC-SA88HA-E
DC 12V signal).
•
Weekly Timer:
On/Off and up to 8 pattern temperatures can
be set for each calendar day. (Initial setting)
•
On/Off Timer:
On/Off can be set once each within 72 hr in
intervals of 5-minute units.
•
Auto-off Timer:
Operation will be switched off after a certain
time elapse. Set time can be changed from
30 min. to 4 hr. at 10 min. intervals.
*Simple Timer and Auto-off Timer
cannot be used at the same time.
• Remote display panel (to be purchased
locally)
• Connector cable for remote display
PAC-SA88HA-E / PAC-725AD
(10 pcs. x PAC-SA88HA-E)
• Relay box (to be purchased locally)
• Remote operation adapter
PAC-SF40RM-E
*Unable to use with wireless remote controller
Remote operation adapter/
Connector cable for remote d
Relay box
Remote operation adapter/
Connector cable for remote d
Relay box
For P Series and S Series Indoor Units
For M Series Indoor Units (New A-control Models Only)
1
2
Remote On/Off
Operation
Remote Display of
Operation Status
Control Details
Major Optional Parts Required
System Examples
Connection Details
•
MAC-333IF-E
(Interface)
• Parts for circuit such as relay
box, lead wire, etc. (to be
purchased locally)
•
MAC-333IF-E
(Interface)
• Parts for circuit to be
purchased locally (DC power
source needed)
• External power source (12V DC)
is required when using
MAC-333IF-E.
Connect the interface to the air
conditioner. Then connect the
locally purchased remote controller
to the terminal in the interface.
Connect the interface to the air
conditioner. Then connect the
locally purchased remote controller
to the terminal in the interface.
On/Off operation is possible from
a remote location.
The operation status
(On/Off) or error signals can be
monitored from a remote location.
Outdoor unit
Indoor unit
MAC-333IF-E
Remote control section
(to be purchased locally)
Switch
• Air conditioner can be started/
stopped remotely.
( 1 and 2 can be used in
combination)
• The On/Off status of air
conditioners can be confirmed
remotely.
( 1 and 2 can be used in
combination)
M Series Indoor Unit
M Series and MXZ Series Outdoor
Indoor Unit
Outdoor Unit
S Series
System Examples
S Series and MXZ Series Outdoor
P Series Indoor Unit
P Series Outdoor
Details
Major Optional Parts Required
• Group of air conditioners can be controlled by MELANS system controller (M-NET).
• MAC-333IF-E (M-NET Interface)
• MELANS System controller
• PAC-SC51KUA (power supply unit)
• PAC-SF83MA-E or PAC-SJ19MA-E
(M-NET converter)
• MELANS System controller
• PAC-SC51KUA (power supply unit)
Details
Major Optional Parts Required
• Wired remote controller can be connected to
indoor unit
• MAC-333IF-E (Interface)
• PAR-21/31MAAU (Wired remote controller)
• PAC-YT53CRAU (Wired remote controller)
• PAR-21/31MAAU (Wired remote controller)
• PAC-YT53CRAU (Wired remote controller)
Standard equipment (for indoor units compatible with wired remote controllers)
Details
Major Optional Parts Required
• One remote controller can control plural air conditioners with the same settings simultaneously.
• One remote controller can control up to 16 refrigerant systems.
(When connected to a MXZ unit, MAC-333IF-E is counted as one system.)
• Up to two remote controller can be connected.
• MAC-333IF-E (Interface)
• PAR-21/31MAAU (Wired remote controller)
• PAC-YT53CRAU (Wired remote controller)
• PAR-21/31MAAU (Wired remote controller)
• PAC-YT53CRAU (Wired remote controller)
Outdoor unit
Outdoor unit
Outdoor unit
Indoor unit
MAC-333IF-E
ME remote controller
(PAR-F27MEA)
PAC-SC51KUA
Power supply
unit
City Multi
indoor unit
PAR-21/31MAAU
PAC-YT53CRAU
MAC-333IF-E
PAR-21/31MAAU
PAC-YT53CRAU
PAR-21/31MAAU Control
PAC-YT53CRAU Control
System Group Control
M-NET Connections
PAR-21/31MAAU
PAC-YT53CRAU
Outdoor
unit
Indoor unit
MAC-333IF-E
MELANS
system controller
(AG-150A etc)
MELANS
system controller
(AG-150A
etc)
PAC-SC51KUA
Power supply
unit
City Multi
indoor unit
PAR-21/31MAAU
PAC-YT53CRAU
Outdoor
unit
Outdoor
unit
Outdoor
unit
Indoor unit
PAR-21/31MAAU
PAC-YT53CRAU
M-NET adapter
PAC-SF83MA-E
PAC-SJ19MA-E
MELANS
system controller
(AG-150A etc)
PAC-SC51KUA
Power supply
kit
PAR-21/31MAAU
PAC-YT53CRAU
PAR-21/31MAAU
PAC-YT53CRAU
Indoor unit
Indoor unit
PAR-21/31MAAU
PAC-YT53CRAU
MAC-333IF-E
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
MAC-333IF-E
PAR-21/31MAAU
PAC-YT53CRAU
Outdoor unit
Indoor unit
MAC-333IF-E
Remote moniter section
(to be purchased locally)
Resistance
LED
Power supply