background image

DUCTLESS AIR CONDITIONERS 

AND HEAT PUMPS 

Mr. Slim systems are unlike any other

products in the HVAC category. Actually they’re
a category in themselves because Mr. Slim is
probably the most unique innovation in air
comfort in two decades and one that has made
us the worldwide leader in ductless.

We designed Mr. Slim air conditioners and

heat pumps to solve cooling and heating
problems that other systems have never
addressed, specifically spot or zone cooling
and heating especially in retrofit situations.
These are voids in comfort that central air and
room air simply can’t fill economically and
attractively.

Where Mr. Slim Fits.

You’ll often encounter a hot or cold spot in

existing buildings that already have large
central systems. Is the answer to remodel and
make way for more ductwork? Obviously that’s
a small fortune. Should you opt for room air?
It’s unsightly at best, expensive to run, and a
real security hazard.

Now you’re beginning to see how Mr. Slim

fits in. It’s the ideal supplemental system for
cooling or heating those smaller zones with
absolutely no ductwork, no remodeling, and
few disruptions to business and traffic. 

Our system is energy

efficient and whisper quiet.

Its remote control keeps all

operating functions and

data within a glance and

in easy reach. And it

neatly tucks away into

corners, blending in

with the room’s decor.

How Mr. Slim
Works.

Basically Mr. Slim is two units: an indoor air

handler and an outdoor compressor unit. 

The two connect via refrigerant lines

through a three  inch diameter opening in the
wall or ceiling. In fact that’s the toughest part of
installation: one hole. 

You can locate the compact outdoor

compressor unit anywhere up to 164 feet away
from the air handler on select models: in many
cases. Many models have a front service panel
that clearly exposes all connections. 

The indoor air handler is as easy to install

as a ceiling fan. And both the indoor and
outdoor units are microprocessor controlled.
Simple remotes let you control all functions. 

MITSUBISHI ELECTRONICS

HVAC DIVISION

COMFORT MADE SIMPLE.

1

Mr.Slim

®

Summary of Contents for Mr.Slim PC24EK

Page 1: ... ER RIIC CA A IIN NC C H HV VA AC C D DI IV VI IS SI IO ON N 3 31 10 00 0 A AV VA AL LO ON N R RI ID DG GE E P PL L S ST TE E 2 20 00 0 N NO OR RC CR RO OS SS S G GA A 3 30 00 07 71 1 C CA AL LL L 7 77 70 0 6 61 13 3 5 58 84 40 0 O OR R 8 80 00 0 4 43 33 3 4 48 82 22 2 P PR RE ES SS S 3 3 F FA AX X 8 80 00 0 8 88 89 9 9 99 90 04 4 ...

Page 2: ...re beginning to see how Mr Slim fits in It s the ideal supplemental system for cooling or heating those smaller zones with absolutely no ductwork no remodeling and few disruptions to business and traffic Our system is energy efficient and whisper quiet Its remote control keeps all operating functions and data within a glance and in easy reach And it neatly tucks away into corners blending in with ...

Page 3: ... e c ca ap pa ac ci it ty y c co oo ol li in ng g a an nd d h he ea at ti in ng g f fo or r l la ar rg ge e a ar re ea a c co om mm me er rc ci ia al l a ap pp pl li ic ca at ti io on ns s P PC C P PC CH H Mr Slim CEILING SUSPENDED UNITS 15 ...

Page 4: ... as low as zero degrees fahrenheit when the optional wind baffle is installed So you can cool spaces such as computer rooms year round Mr Slim heat pumps also feature automatic cooling heating changeover for simple control and lower maintenance You never have to readjust the unit Air Flow These units offer a wide choice of air flow directions In the heating mode the vanes automatically set the flo...

Page 5: ...ions W 50 7 16 D 26 13 16 H 10 1 8 PC30EK Cooling capacity 31 000 BTU h SEER 10 4 Dimensions W 50 7 16 D 26 13 16 H 10 1 8 PC36EK Cooling capacity 36 500 BTU h SEER 10 2 Dimensions W 62 1 4 D 26 13 16 H 10 1 8 PC42EK Cooling capacity 42 500 BTU h SEER 10 0 Dimensions W 62 1 4 D 26 13 16 H 10 1 8 Heat Pumps PCH24EK PCH24EK Cooling capacity 24 000 BTU h SEER 10 3 Heating capacity 27 000 BTU h 33 500...

Page 6: ...5 Cond Drain Connection OD in 1 1 1 1 1 1 1 1 W in 50 7 16 50 7 16 62 1 4 62 1 4 50 7 16 50 7 16 62 1 4 62 1 4 Dimensions D in 26 13 16 26 13 16 26 13 16 26 13 16 26 13 16 26 13 16 26 13 16 26 13 16 H in 10 1 8 10 1 8 10 1 8 10 1 8 10 1 8 10 1 8 10 1 8 10 1 8 Weight lbs 93 93 115 115 97 97 119 119 OUTDOOR UNIT PU24EK PU30EK PU36EK PU42EK PU24EK PU30EK PU36EK PU42EK External Finish Munsell 5Y 7 1 S...

Page 7: ...e c ca ap pa ac ci it ty y c co oo ol li in ng g a an nd d h he ea at ti in ng g f fo or r l la ar rg ge e a ar re ea a c co om mm me er rc ci ia al l a ap pp pl li ic ca at ti io on ns s P PL L P PL LH H Mr Slim CEILING MOUNTED CASSETTES 19 ...

Page 8: ...eratures as low as zero degrees fahrenheit when the optional wind baffle is installed You can therefore cool spaces such as computer rooms year round Mr Slim heat pumps also feature automatic cooling heating changeover for simple control and lower maintenance You never have to readjust the unit Air Flow These ceiling cassettes offer multi directional air flow in a number of various patterns to dir...

Page 9: ... 32 1 4 H 10 1 8 PL18FK Cooling capacity 18 400 BTU h SEER 10 2 Cassette Dimensions W 32 1 4 D 32 1 4 H 10 1 8 PL24FK Cooling capacity 23 600 BTU h SEER 10 0 Cassette Dimensions W 32 1 4 D 32 1 4 H 10 1 8 PL30FK PL30FK Cooling capacity 31 000 BTU h SEER 10 4 Cassette Dimensions W 52 3 4 D 32 1 4 H 10 1 8 PL34FK Cooling capacity 32 400 BTU h SEER 10 0 Cassette Dimensions W 52 3 4 D 32 1 4 H 10 1 8 ...

Page 10: ... 4 32 1 4 32 1 4 32 1 4 32 1 4 32 1 4 32 1 4 32 1 4 32 1 4 32 1 4 32 1 4 H in 10 1 8 10 1 8 10 1 8 10 1 8 10 1 8 10 1 8 10 1 8 10 1 8 10 1 8 10 1 8 10 1 8 Weight 60 64 64 99 99 101 66 66 104 104 104 External Finish Marble White Decorative W in 36 5 8 36 5 8 36 5 8 57 1 8 57 1 8 57 1 8 36 5 8 36 5 8 57 1 8 57 1 8 57 1 8 Indoor grille Dimensions D in 36 5 8 36 5 8 36 5 8 36 5 8 36 5 8 36 5 8 36 5 8 ...

Page 11: ... PL18FK PLH18FK PK12EK PL12FK PK24EK PKH24EK PC24EK PCH24FK PL24FK PK24EK PK30EK PKH30EK PL30FK PLH30FK PC30EK PCH30EK PL36FK PLH36FK PC36EK PCH36EK PL42FK2 PC42EK PLH42FK PCH42EK MS09EW MS15EN Max Height Difference ft 25 25 25 130 164 Max Tubing Length ft 49 65 49 130 164 Liquid 1 4 3 8 1 2 Gas 3 8 1 2 3 8 5 8 5 8 3 4 7 8 Connection Method Flared Refrigerant Tubing Tubing OD N MODEL Cooling Heati...