Summary of Contents for Mr. Slim MSZ-GE15NA

Page 1: ... plug into the outlet make sure that there is no dust blockage or loose parts both in the outlet and on the plug Verify that the power supply plug is completely in the outlet If there is dust blockage or loose parts on the power supply plug or the outlet it could cause electric shock or fire If loose parts are found on the power supply plug replace it Securely attach the electrical cover to the in...

Page 2: ...seaside Where sulfide gas is generated such as a hot spring Where there is high frequency or wireless equipment 1 3 SPECIFICATIONS 1 3 1 POWER SUPPLY AND INDOOR OUTDOOR WIRE CONNECTION Power should be taken from an exclusive branched circuit Wiring work should be based on applicable technical stand ards Wiring connections should be made following the diagram Securely tighten screws Connecting wire...

Page 3: ...t screw F k __ After the leak test apply insulating mate _ _ _7 C When the piping is to be attached to a wall _b _i_ _ I _ _ G comprised of tin plate or metal netting use _ _ chemically treated wooden piece 25 32 in 1_1 _ 20mm orthickerbetweenthewalland 6_ _ the piping or wrap insulation vinyl tape 7 I _ _ I _ G _ 3 to8turns around the piping _ff _ _ _ _ To use existing piping perform COOL k opera...

Page 4: ...Elbow joint should appear less than 1 3 16 in 30 mm outside Fig 2 6 Process the end of ground wire Fig 3 Connect it to the ground terminal of electrical parts box 7 Process the end of indoor outdoor unit connecting wire A Fig 3 Attach it to the terminal block Be careful not to make mis wiring Attach the wire to the terminal block securely so that its core cannot be seen and no external force affec...

Page 5: ...nect the refrigerant piping with the extension pipe B 9 Attach the lower part of the indoor unit into the installation plate 1 _ _ain cap Fig 1 Fig 2 _i _ _ Drain hose Fig 3 Fig 5 Fig 4 Rear or bottom piping 1 Place the refrigerant piping and the drain hose together then firmly apply piping tape G from the end 2 Insert the piping and the drain hose into the wall hole sleeve C and attach the up per...

Page 6: ...er supply cord K Indoor outdoor unit connecting wire A to conduit cover TB support 3 2 FLARE CONNECTION t Cut the copper pipe as straight as possible with a pipe cutter Fig 1 2 2 Remove all burrs from the cut section of the pipe ensuring that precautions are taken to avoid getting metal shavings into the piping Fig 3 3 Remove flare nuts attached to indoor and outdoor units then put them on pipe 4 ...

Page 7: ...nnecting wire A After the test run emergency COOL mode 75 F 24 C COOL will start 3 To stop operation press the E O SW several times until all LED lamps turn off Refer to operating instructions for W JJ details _Emergency operation switch E O SW Checking the remote infrared signal reception Press the ON OFF button on the remote controller and listen for an audible indicator from the indoor unit Pre...

Page 8: ... into the atmosphere 1 Connect the gauge manifold valve to the service port of the stop valve on the gas pipe side of the outdoor unit 2 Fully close the stop valve on the liquid pipe side of the outdoor unit 3 Close the stop valve on the gas pipe side of the outdoor unit almost completely so that it can be easily closed fully when the pressure gauge shows 0 MPa Gauge 0 Ibf in 2 0 kgf cm2 4 Start t...