27
L AREA R
POWER
No.
Abnormal
point
Operation indicator lamp
Symptom
Condition
Correspondence
1
MXZ type
Operation
mode
setting
POWER lamp is lighted.
AREA lamps
fl
ash.
2.5-second OFF
Outdoor unit
operates but
indoor unit does
not operate.
The operation mode of the each indoor unit
is differently set to COOL (includes DRY) and
HEAT at the same time, the operation mode
of the indoor unit that has operated at
fi
rst has
the priority.
Unify the operation mode.
Refer to outdoor unit service