background image

En-9

● OPERATING INSTRUCTIONS ●

Even if these items are checked, when the unit does not recover from the 
trouble, stop using the air conditioner and consult your dealer.

Symptom

Explanation & Check points

Indoor Unit

The unit cannot be operated.

• Is the breaker turned on?
• Is the power supply plug connected?
• Is the ON timer set?

Page 7

The horizontal vane does not
move.

• Is the horizontal vane installed correctly?
• Is the fan guard deformed?

The unit cannot be operated
for about 3 minutes when
restarted.

• This protects the unit according to instruc-

tions from the microprocessor. Please
wait.

Mist is discharged from the air
outlet of the indoor unit.

• The cool air from the unit rapidly cools mois-

ture in the air inside the room, and it turns
into mist.

The swing operation of the
HORIZONTAL VANE is
suspended for a while, then
restarted.

• This is for the swing operation of the HORI-

ZONTAL VANE to be performed normally.

The air flow direction changes 
during operation.
The direction of the horizontal
vane cannot be adjusted with
the remote controller.

• When the unit is operated in COOL or DRY

mode, if the operation continues with air
blowing down for around 1 hour, the direction
of the air flow is automatically set to position 
(1) to prevent water from condensing and
dripping.

•  In the heating operation, if the air flow tem-

perature is too low or when defrosting is be-
ing done, the horizontal vane is automatically
set to horizontal position.

The operation is stopped for
about 10 minutes in the heat-
ing operation.

• Defrosting of the outdoor unit is being

done.

  Since this is completed in max.10 minutes, 

please wait. (When the outside temperature
is too low and humidity is too high, frost is
formed.)

The unit starts operation by
itself when the main power
is turned on, though it isn’t
operated with the remote
controller.

• These models are equipped with an auto re-

start function. When the main power is turned
off without stopping the unit with the remote
controller and is turned on again, the unit
starts operation automatically in the same
mode as the one set with the remote control-
ler just before the shut off of the main power.
Refer to “Auto restart function”

page 5

.

Multi system

The indoor unit which is not
operating becomes warm and
a sound, similar to water flow-
ing, is heard from the unit.

• A small amount of refrigerant continues to

flow into the indoor unit even though it is 
not operating.

When heating operation is
selected, operation does not
start right away.

• When operation is started during defrosting

of outdoor unit is done, it takes a few minutes
(max. 10 minutes) to blow out warm air.

Outdoor Unit

Water leaks from the outdoor
unit.

• During COOL and DRY operations, pipe or

pipe connecting sections are cooled and this
causes water to condense.

• In the heating operation, water condensed

on the heat exchanger drips down.

• In the heating operation, the defrosting op-

eration makes water frozen on the outdoor
unit melt and drip down.

The fan of the outdoor unit
does not rotate even though
the compressor is running.
Even if the fan starts to rotate,
it stops soon.

• When the outside temperature is low dur-

ing cooling operation, the fan operates
intermittently to maintain sufficient cooling
capacity.

White smoke is discharged
from the outdoor unit.

• In the heating operation, vapor generated

by the defrosting operation looks like white
smoke.

Symptom

Explanation & Check points

Remote controller

The display on the remote
controller does not appear
or it is dim. The indoor unit
does not respond to the
remote control signal.

•  Are the batteries exhausted? 

Page 4

• Is the polarity (+, -) of the batteries correct?

Page 4

• Are any buttons on the remote controller of

other electric appliances being pressed?

Does not cool or heat

The room cannot be cooled
or heated sufficiently.

• Is the temperature setting appropriate?

Page 5

• Is the fan setting appropriate? Please

change fan speed to higher setting.

Page 6

•  Are the filters clean? 

Page 8

•  Is the fan or heat exchanger of the indoor unit 

clean?

• Are there any obstacles blocking the air inlet

or outlet of the indoor or outdoor unit?

• Is a window or door open?

The room cannot be cooled
sufficiently.

• When a ventilation fan or a gas cooker is

used in a room, the cooling load increases,
resulting in an insufficient cooling effect.

• When the outside temperature is high, the

cooling effect may not be sufficient.

The room cannot be heated
sufficiently.

• When the outside temperature is low, the

heating effect may not be sufficient.

Air does not blow out soon in
the heating operation.

• Please wait as the unit is preparing to blow

out warm air.

Airflow

The air from the indoor unit
smells strange.

•  Are the filters clean? 

Page 8

•  Is the fan or heat exchanger of the indoor unit 

clean?

• The unit may suck in an odor adhering to the

wall, carpet, furniture, cloth, etc. and blow it
out with the air.

Sound

Cracking sound is heard.

• This sound is generated by the expansion/

contraction of the front panel, etc. due to
change in temperature.

The sound as burbling is
heard.

• This sound is heard when the outside air is

absorbed from the drain hose by turning on
the range hood or the ventilation fan, making
water flowing in the drain hose to spout out.

 This sound is also heard when the outside air

blows into the drain hose in case the outside
wind is strong.

Mechanical sound is heard
from the indoor unit.

• This is the switching sound in turning on/off

the fan or the compressor.

The sound of water flowing 
is heard.

• This is the sound of refrigerant or condensed

water flowing in the unit.

Hissing sound is sometimes
heard.

•  This is the sound when the flow of refrigerant 

inside the unit is switched.

In the following cases, stop using the air conditioner and consult your 
dealer.

• When water leaks or drips from the indoor unit.
• When the upper operation indicator lamp blinks.
• When the breaker trips frequently.
• The remote control signal is not received in a room where an electronic ON/OFF

type fluorescent lamp (inverter-type fluorescent lamp, etc.) is used.

• Operation of the air conditioner interferes with radio or TV reception. An ampli-

fier may be required for the affected device.

• When an abnormal sound is heard.

W

HEN YOU THINK THAT TROUBLE HAS OCCURRED

Summary of Contents for Mr.SLIM MSZ-A09NA-1

Page 1: ...ONERS INDOOR UNIT MSZ A09NA 1 MSZ A12NA 1 MSZ A15NA 1 MSZ A17NA 1 English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read this operating in structions before use MANUAL DE INSTRUCCIONES ...

Page 2: ...nstalled relocated or repaired by the user An improperly handled air conditioner may cause fire or electric shock Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside rotates at high speeds during operation In case of an abnormal condition such as a burning smell stop the air conditioner and disconnect the power plug or turn the ...

Page 3: ...rn the breaker OFF when you hear thunder and there is a possibility of a lightning strike The unit may be damaged if lightning strikes After the air conditioner is used for several seasons per form inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor or clog the drain passage and cause water to leak from the indoor unit Consult your deale...

Page 4: ...Operation indicator lamp Remote control receiving section Horizontal vane Vertical vane Air outlet Fan Air filter Catechin air filter Air inlet Heat exchanger Front panel Air cleaning filter Anti Allergy Enzyme Filter Indoor unit Emergency operation switch Page 5 Remote controller holder Install the remote controller holder to a place where the signal can be received by the indoor unit Operation disp...

Page 5: ...ontroller batteries PREPARATION BEFORE OPERATION R E S E T C L O C K 1 Remove the front lid 2 Insert AAA alkaline batteries 3 Install the front lid Press RESET and CLOCK gently using a thin stick If the RESET button is not pressed the remote controller may not operate correctly R E S E T C L O C K 1 Press RESET 2 Press CLOCK 4 Press CLOCK again 3 Press the TIME buttons to set the time Each press i...

Page 6: ...to the difference between the room temperature and the set temperature During AUTO mode the unit changes mode COOL HEAT when the room temperature is 4 F 2 C away from the set temperature for more than 15 minutes Note During multi system operation the unit may not be able to switch opera tion mode between COOL and HEAT In this case the indoor unit be comes standby mode COOL mode Enjoy cool air at y...

Page 7: ... comfortable airflow distribution N To change the horizontal airflow direction Move the vertical vane manually before starting operation AUTO Low Med High AUTO 1 2 3 4 SWING ECONO COOL OPERATION Press during COOL mode page 5 to start ECONO COOL operation The unit performs swing operation vertically in various cycle according to the temperature of the unit Set temperature is set 4 F 2 C higher autom...

Page 8: ...time or blinks Make sure that the current time is set correctly Page 4 2 Press Increase and Decrease to set the time of timer Each press increases or decreases the set time by 10 minutes Press or again to cancel timer Note ON and OFF timers can be used in combination mark indicates the order of timer operations If power failure occurs while ON OFF timer is set see page 5 Auto restart function ...

Page 9: ...ts Catechin also offers excellent deodorizing characteristics Catechin air filter uses this compound to not only improve air quality but also prevent the spread of bacteria and viruses in the room CLEANING Switch off the power supply or turn off the breaker before cleaning Be careful not to touch the metal parts with your hands Do not use benzine thinner polishing powder or insecticide Use only dil...

Page 10: ... rotate even though the compressor is running Even if the fan starts to rotate it stops soon When the outside temperature is low dur ing cooling operation the fan operates intermittently to maintain sufficient cooling capacity White smoke is discharged from the outdoor unit In the heating operation vapor generated by the defrosting operation looks like white smoke Symptom Explanation Check points ...

Page 11: ...1 Set to the highest temperature in manual COOL mode and operate for 3 to 4 hours Page 5 This dries the inside of the unit 2 Press to stop the operation 3 Turn off the breaker and or disconnect the power sup ply plug 4 Remove all batteries from the remote controller When using the air conditioner again 1 Clean the air filters Page 8 2 Check that the air inlet and outlet of the indoor and outdoor un...

Page 12: ...4299 14th Avenue Markham Ontario L3R 0J2 Canada SG79Y960H01 ...

Reviews: