 WARNING

Do not connect the power cord to an intermediate point, 

use an extension cord, or connect multiple devices to a 

single AC outlet.

•  This may cause overheating, 

fi

 re, or electric shock.

Make sure the power plug is free of dirt and insert it se-

curely into the outlet.

•  A dirty plug may cause 

fi

 re or electric shock.

Do not bundle, pull, damage, or modify the power cord, and 

do not apply heat or place heavy objects on it.

•  This may cause 

fi

 re or electric shock.

Do not turn the breaker OFF/ON or disconnect/connect the 

power plug during operation.

•  This may create sparks, which can cause 

fi

 re.

•  After the indoor unit is switched OFF with the remote con-

troller, make sure to turn the breaker OFF or disconnect the 

power plug. 

Do not expose your body directly to cool air for a prolonged 

length of time.

•  This could be detrimental to your health.

The unit should not be installed, relocated, disassembled, 

altered, or repaired by the user.

•  An improperly handled air conditioner may cause 

fi

 re, electric 

shock, injury, or water leakage, etc. Consult your dealer.

•  If the power supply cord is damaged, it must be replaced by the 

manufacturer or its service agent in order to avoid a hazard.

When installing, relocating, or servicing the unit, make 

sure that no substance other than the speci

fi

 ed refrigerant 

(R410A) enters the refrigerant circuit.

•  Any presence of foreign substance such as air can cause ab-

normal pressure rise and may result in explosion or injury.

•  The use of any refrigerant other than that speci

fi

 ed for the 

system will cause mechanical failure, system malfunction, 

or unit breakdown. In the worst case, this could lead to a 

serious impediment to securing product safety.

•  Since rotating parts and parts which could cause an electric shock are used 

in this product, be sure to read these “Safety Precautions” before use.

•  Since the cautionary items shown here are important for safety, be sure to 

observe them.

•  After reading this manual, keep it together with the installation manual in a 

handy place for easy reference.

•  Be sure to receive a guarantee card from your dealer and check that the 

purchased data and shop name, etc. are entered correctly.

Marks and their meanings

 WARNING :

Incorrect handling could cause serious hazard, such as 
death, serious injury, etc. with a high probability.

 CAUTION :

Incorrect handling could cause serious hazard depending 
on the conditions.

This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental capabili-

ties, or lack of experience and knowledge, unless they have 

been given supervision or instruction concerning use of the 

appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not 

play with the appliance.

 

Do not insert your 

fi

 nger, a stick, or other objects into the 

air inlet or outlet.

•  This may cause injury, since the fan inside rotates at high 

speeds during operation.

  

In case of an abnormal condition (such as a burning smell), 

stop the air conditioner and disconnect the power plug or 

turn the breaker OFF.

•  A continued operation in the abnormal state may cause a 

malfunction, 

fi

 re, or electric shock. In this case, consult your 

dealer.

When the air conditioner does not cool, there is a possibil-

ity of refrigerant leakage. In this case, consult your dealer. 

If a repair involves recharging the unit with refrigerant, ask 

the service technician for details.

•  The refrigerant used in the air conditioner is safe. Normally, 

it does not leak. However, if refrigerant leaks and comes in 

contact with a heat source such as a fan heater, kerosene 

heater, or cooking stove, it will create a harmful gas.

The user should never attempt to wash the inside of the 

indoor unit. Should the inside of the unit require cleaning, 

contact your dealer.

•  Unsuitable detergent may cause damage to plastic material 

inside the unit, which may result in water leakage. Should 

detergent come in contact with electrical parts or the motor, 

it will result in a malfunction, smoke, or 

fi

 re.

Meanings of symbols used in this manual

 :  Be sure not to do.

 :  Be sure to follow the instruction.

 :  Never insert your 

fi

 nger or stick, etc.

 :  Never step onto the indoor/outdoor unit and do not put anything on them.

 :  Danger of electric shock. Be careful.

 :  Be sure to disconnect the power supply plug from the power outlet.

 :  Be sure to shut off the power.

S

AFETY PRECAUTIONS

C

ONTENTS

 SAFETY PRECAUTIONS 

1

 NAME OF EACH PART 

3

 PREPARATION BEFORE OPERATION 

3

 SELECTING OPERATION MODES 

4

  FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT 

5

 LONG OPERATION 

5

 POWERFUL OPERATION 

5

 I-SAVE OPERATION  

6

 ECONO COOL OPERATION  

6

 TIMER OPERATION (ON/OFF TIMER) 

6

 WEEKLY TIMER OPERATION 

7

 CLEANING 

8

 WHEN YOU THINK THAT TROUBLE HAS OCCURRED 

9

 WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME 

10

 INSTALLATION PLACE AND ELECTRICAL WORK 

10

 SPECIFICATIONS 

10

Summary of Contents for Mr.Slim MSY-GK18VA

Page 1: ...SPLIT TYPE AIR CONDITIONERS INDOOR UNIT MSY GK18VA MSY GK24VA English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating instructions before use ...

Page 2: ...rrect handling could cause serious hazard depending on the conditions This appliance is not intended for use by persons including children with reduced physical sensory or mental capabili ties or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure tha...

Page 3: ...attery fluid comes in contact with your eyes wash them thoroughly with clean water and immediately seek medical attention Ensure that the area is well ventilated when the unit is oper ated together with a combustion appliance Inadequate ventilation may cause oxygen starvation Turn the breaker OFF when you hear thunder and there is a possibility of a lightning strike The unit may be damaged if ligh...

Page 4: ...es when pressed longer Indoor unit Remote controller Outdoor units may be different in appearance 1 Remove the front lid 2 Insert AAA alkaline batteries 3 Install the front lid 4 Press RESET Air cleaning filter Electrostatic anti allergy enzyme filter Signal transmitting section Distance of signal About 6 m Beep s is are heard from the indoor unit when the signal is received Operation display sect...

Page 5: ...peration 2 Press to select operation mode Each press changes mode in the following order 3 Press or to set the temperature Each press raises or lowers the temperature by 1 C Press to stop the operation The same setting is selected the next time by simply pressing Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically sta...

Page 6: ...COOL DRY the vane automatically moves to the upper position after 0 5 to 1 hour to prevent any condensation from dripping Swing The vane moves up and down intermittently AUTO Silent Low Med High Super High AUTO 1 2 3 4 5 SWING LONG OPERATION Press to start LONG operation Fan speed increases and the horizontal vane moves to the position for LONG mode Air reaches to longer distance Press again to ca...

Page 7: ...COOL OPERATION Press during COOL mode page 4 to start ECONO COOL operation The unit performs swing operation vertically in various cycles according to the temperature of airflow Press again to cancel ECONO COOL operation ECONO COOL operation is canceled when the VANE LONG or POWERFUL button is pressed What is ECONO COOL Swing airflow change of airflow makes you feel cooler than stationary airflow ...

Page 8: ... Press to enter the weekly timer setting mode and press and hold for 5 seconds to erase all weekly timer settings Point the remote controller toward the indoor unit 5 Press to turn the weekly timer ON lights When the weekly timer is ON the day of the week whose timer setting is complete will light Press again to turn the weekly timer OFF goes out Note The saved settings will not be cleared when th...

Page 9: ...emi permanent antibacterial and deodorizing characteristics for the filter Nano platinum surpasses the catechin a bioflavonoid that is found in green tea in performance Nano platinum filter uses this compound not only to improve air quality but also to eliminate bacteria and viruses This air filter has a semi permanent lasting effect even after washing it with water Air cleaning filter Electrostat...

Page 10: ...Is the temperature setting appropriate Page 4 Is the fan setting appropriate Please change fan speed to higher setting Page 5 Are the filters clean Page 8 Is the fan or heat exchanger of the indoor unit clean Page 8 Are there any obstacles blocking the air inlet or outlet of the indoor or outdoor unit Is a window or door open When a ventilation fan or a gas cooker is used in a room the cooling loa...

Page 11: ...the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception 1 Set to the highest temperature in manual COOL mode and operate for 3 to 4 hours Page 4 This dries the inside of the unit Moisture in the air conditioner contributes ...

Page 12: ... างไม ถูกวิธี อาจเป นสาเหตุให เกิดอันตรายอย าง รุนแรง ขึ นอยู กับสภาพการใช งานนั นๆ ไม ควรให บุคคล รวมทั งเด กเล ก ที มีสภาพร างกายไม แข งแรง สภาพ การรับรู หรือจิตใจไม ปกติ หรือขาดประสบการณ และความรู ความเข าใจ นําอุปกรณ นี ไปใช งาน เว นแต จะอยู ในการควบคุมดูแล หรือได รับคําแนะนําในการใช งานจากผู ที รับผิดชอบต อความปลอดภัย ของบุคคลนั นๆ ได เด กเล กควรได รับการดูแลเพื อป องกันไม ให นําอุปกรณ นี ไปเ...

Page 13: ...องเหลวจากแบตเตอรี รั วออกมาเป อนผิว เสื อผ า ให ล างออกด วยนํ า สะอาด หากของเหลวจากแบตเตอรี เข าตา ให ล างออกด วยนํ าสะอาด และ ปรึกษาแพทย โดยทันที ควรตรวจให แน ใจว าพื นที นั นจะมีการระบายอากาศที ดีขณะที เครื อง ปรับอากาศทํางานพร อมกับเครื องใช ที มีการเผาไหม การระบายอากาศที ไม ดีเพียงพออาจทําให เกิดภาวะขาดออกซิเจนได สับเบรกเกอร ลง หากท านได ยินเสียงฟ าร อง และมีความเป นไปได ที จะเกิดฟ าผ า เครื อ...

Page 14: ...นวนอน หน า 5 ติดตั งที วางรีโมทคอนโทรลใน ตําแหน งที เครื องภายในบ าน สามารถรับสัญญาณได เมื อไม ใช งานรีโมทคอนโทรล โปรดเก บไว ที แท นเสียบนี ส วนแสดงผล 3 กดปุ ม DAY เพื อตั งค าวันที ใช รีโมทคอนโทรลที จัดเตรียมมา กับเครื องเท านั น ห ามใช รีโมทคอนโทรลอันอื น หากติดตั งเครื องในบ าน 2 เครื องขึ น ไปไว ใกล เคียงกัน เครื องในบ าน เครื องใดเครื องหนึ งซึ งไม ต องการให ทํางานอาจมีการตอบสนองต อ รีโมทคอนโ...

Page 15: ... งาน I FEEL COOL DRY FAN ไฟแสดงการทํางาน ไฟแสดงการทํางานจะแสดงสถานะการทํางานของเครื องปรับอากาศ การแสดงการทํางาน สถานะการทํางาน อุณหภูมิห อง เครื องปรับอากาศกําลังปรับอุณหภูมิ ให ได อุณหภูมิตามที ตั งไว สูงกว าอุณหภูมิที ตั งไว อย างน อย 2 องศา เซลเซียส อุณหภูมิห องใกล เคียงกับอุณหภูมิตาม ที ตั งไว ตํ ากว าอุณหภูมิที ตั งไว ประมาณ 1 หรือ 2 องศา เซลเซียส สว าง ไม สว าง ไฟแสดงการทํางาน ระบบการทํางาน...

Page 16: ... น ลง ตําแหน งที ตั งค าไว หรือถ าในระหว างการทํางาน โหมด AUTO อัตโนมัติ ตําแหน งทิศทางลม จะเป าลงด านล าง ไม สามารถตั งอุณหภูมิได ในขณะที เครื องทํางานในระบบ POWERFUL กด อีกครั งเพื อยกเลิกระบบพลังแรง POWERFUL ระบบพลังแรง POWERFUL จะถูกยกเลิกโดยอัตโนมัติภายใน 15 นาที หรือเมื อ กดปุ มเป ด ป ดเครื อง ON OFF ปุ มควบคุมความเร วใบพัด FAN ปุ มระบบ ทําความเย นแบบ ECONO COOL หรือปุ มระบบทําความเย นแบบ i ...

Page 17: ... 3 กดปุ ม หรือ อีกครั งเพื อยกเลิกการตั งเวลา หมายเหตุ สามารถตั งเวลาเป ด ON และป ด OFF พร อมกันได สัญลักษณ แสดงถึงลําดับการ ทํางานของการตั งเวลา หากกระแสไฟฟ าขัดข องในขณะโปรแกรมการตั งเวลาเป ดป ด ON OFF ทํางานอยู ดู หน า 4 ฟ งก ชันการเริ มต นการทํางานใหม โดยอัตโนมัติ การตั งเวลาเป ด ป ดเครื อง การตั งเวลาON OFF ระบบ I SAVE 1 กดปุ ม ระหว างอยู ในโหมด COOL ECONO COOL เพื อเลือกโหมด i save 2 ตั งอุณ...

Page 18: ... ไม ต องกด ทุกครั งสําหรับแต ละค า สามารถกด เพียงครั งเดียวหลังจากตั ง ค าทั งหมดเสร จแล ว ค าการตั งเวลารายสัปดาห ทั งหมดจะถูกบันทึกไว กด เพื อเข าสู โหมดการตั งเวลารายสัปดาห แล วกด ค างไว 5 วินาที โดยชี รีโมทคอนโทรลไปที เครื องภายในบ าน เพื อลบค าการตั งเวลารายสัปดาห ทั งหมด 5 กด เพื อเป ดการตั งเวลารายสัปดาห จะสว างขึ น เมื อเป ดการตั งเวลารายสัปดาห วันในรอบสัปดาห ที ตั งค าไว แล วจะสว างขึ น ก...

Page 19: ...บถาวร ถือว านาโนแพลตินัมมีประสิทธิภาพเหนือกว าสาร คาเตคิน สารไบโอฟลาโวนอยด ที พบในชาเขียว แผ นกรองนาโนแพลตินัมไม เพียงแต ใช สารประกอบนี ในการปรับคุณภาพอากาศเท านั น ยังใช กําจัดเชื อแบคทีเรียและไวรัสอีกด วย แผ นกรองอากาศนี มีประสิทธิภาพในการกรองอากาศได เกือบถาวรแม ว าจะผ านการล างทํา ความสะอาดด วยนํ าแล วก ตาม แผ นกรองฟอกอากาศ แผ นกรองที มีเอนไซม ต านสารก ออาการแพ แบบอิเล กโทรสเตติก ทุกๆ 3 เดือน ก...

Page 20: ...งเครื องภายใน บ านกําลังกะพริบ ใส บานเกล ดปรับทิศทางลมขึ น ลงถูกต องหรือไม หน า 8 บานเกล ดปรับทิศทางลมขึ น ลงไม เคลื อนที ติดตั งบานเกล ดปรับทิศทางลมขึ น ลงและบานเกล ด ปรับทิศทางลมซ าย ขวาถูกต องหรือไม หน า 8 เครื องปรับอากาศไม ทํางานช วงเวลา 3 นาที หลังจากเริ มเป ดเครื อง เป นการป องกันเครื องตามคําสั งจากไมโคร โปรเซสเซอร กรุณารอสักครู มีหมอกออกจากช องลมออกของ เครื องภายในบ าน ลมเย นจากตัวเครื อง...

Page 21: ...อกของเครื อง ภายในและภายนอกบ าน 3 ตรวจสอบว าต อสายดินถูกต องแล ว 4 ดู การเตรียมตัวก อนใช งาน และปฏิบัติตามคําแนะนํา หน า 3 เมื อไม ได ใช เครื องปรับอากาศเป นเวลานาน รุ น MSY GK18VA MSY GK24VA ขนาด สูง กว าง ลึก มม เครื องภายในบ าน 325 1100 238 325 1100 238 เครื องภายนอกบ าน 550 800 285 880 840 330 นํ าหนัก กก เครื องภายในบ าน 16 16 เครื องภายนอกบ าน 35 50 หมายเหตุ 1 เงื อนไขการประเมิน ทําความเย น ...

Page 22: ...VG79D555H01 ...

Reviews: