En-9
• OPERATING INSTRUCTIONS •
Installation place
Avoid installing the air conditioner in the following places.
• Where there is much machine oil.
• Salty places such as the seaside.
• Where
sul
fi
de gas is generated such as a hot spring.
• Where oil is splashed or where the area is
fi
lled with oily smoke.
• Where there is high-frequency or wireless equipment.
• Where the air from the outdoor unit air outlet is blocked.
• Where the operation sound or air from the outdoor unit does not bother the
house next door.
Electrical work
• Provide an exclusive circuit for the power supply of the air conditioner.
• Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
I
NSTALLATION PLACE AND
ELECTRICAL WORK
S
PECIFICATIONS
To prevent the effects
of a
fl
uorescent lamp,
keep as far apart as
possible.
wall, etc.
Inverter-type
fl
uorescent lamp
Keep a space to
prevent the pic-
ture distortion or
the noise.
1 m
or more
Radio
100 mm
or more
Well-
ventilated dry
place
200 mm
or more
TV
Cordless
phone or
Portable
phone
3 m or
more
1 m
or more
The installation location of the outdoor unit should
be at least 3 m away from the antennas for TV sets,
radios, etc. In areas where the reception is weak,
provide greater space between the outdoor unit and
the antenna of the affected device if operation of the air
conditioner interferes with radio or TV reception.
1
Set to the highest temperature in manual COOL mode,
and operate for 3 to 4 hours.
Page 4
• This dries the inside of the unit.
• Moisture in the air conditioner contributes to growth of fungi, such as
mold.
2
Press
to stop the operation.
3
Turn off the breaker and/or disconnect the power
supply plug.
4
Remove all batteries from the remote controller.
When using the air conditioner again:
1
Clean the air
fi
lter.
Page 7
2
Check that the air inlet and outlet of the indoor and
outdoor units are not blocked.
3
Check that the earth is connected correctly.
4
Refer to the “PREPARATION BEFORE OPERATION”,
and follow the instructions.
Page 3
W
HEN THE AIR CONDITIONER IS NOT
GOING TO BE USED FOR A LONG TIME
Model
MSY-GK09VA
MSY-GK13VA
MSY-GK15VA
Dimensions
H x W x D (mm)
Indoor
295 x 798 x 232
295 x 798 x 232
295 x 798 x 232
Outdoor
550 x 800 x 285
550 x 800 x 285
550 x 800 x 285
Weight (kg)
Indoor
10
10
10
Outdoor
29
29
35
Note:
1. Rating condition
Cooling — Indoor:
27°C DB, 19°C WB
Outdoor: 35°C
DB
Indoor
Outdoor
Upper limit
32°C DB
23°C WB
46°C DB
—
Lower limit
21°C DB
15°C WB
21°C DB
—
2. Guaranteed operating range
DB: Dry Bulb
WB: Wet Bulb
Summary of Contents for Mr.Slim MSY-GK09VA