Mitsubishi Electric Mr.Slim MSY-D30NA Installation Manual Download Page 3

Summary of Contents for Mr.Slim MSY-D30NA

Page 1: ...r loose parts both in the outlet and on the plug Verify that the power supply plug is completely in the outlet If there is dust blockage or loose parts on the power supply plug or the outlet it could cause electric shock or fire If loose parts are found on the power supply plug replace it Securely attach the electrical cover to the indoor unit and the service panel to the outdoor unit If the elect...

Page 2: ...tlet side Avoid the following places for installation where air conditioner trouble is liable to occur Where flammable gas could leak Where there is an excessive amount of machine oil in the air Salty places such as the seaside Where sulfide gas is generated such as a hot spring Where there is high frequency or wireless equipment 1 3 SPECIFICATIONS 1 3 1 POWER SUPPLY AND INDOOR OUTDOOR WiRE CONNEC...

Page 3: ...vent indoor out door connecting wire A from contacting metal parts in the wall and to protect the wiring from rodents iy_ j_wall_ holecover D indoor umt _Seal the wall hole _ J_r _ gap wllh puHy 14 Wall hole V_I m s_ _ _ch the_pe t i _ _ waft wdh pipe a w _ Ltachment strap E d Cut off the extra length _ Pipe attach L _ mentstrap E _ Attachment screw F F K After the leak test apply insulating mate ...

Page 4: ...minal block securely so that its core cannot be seen and no external force affects the connecting section of the terminal block 11 Firmly tighten the terminal screws After tightening verify that the wires are tightly fas tened 12 Reinstall conduit plate t3 Reinstall cable guide 14 According to the piping direction remove the shaded part of the left side of box Fig 4 or corner box Fig 5 15 Reinstal...

Page 5: ... unit otherwise water could drip down from the drain hose 1 Place the refrigerant piping and the drain hose together then firmly apply felt tape 7 from the end Felt tape 7 overlap width should be t 3 the tape width Use a bandage stopper at the end of felt tape 7 2 Pull out the drain cap at the back right of the indoor unit Fig 1 Hold the convex section at the end and pull the drain cap 3 Pull out ...

Page 6: ...upplied drain hose I Fig 2 When connecting the drain hose to a hard vinyl chloride pipe be sure to insert it securely into the pipe Fig 3 O Downward slope Soft hose I D 19 32 in 15 mm Fig 1 Fig 2 27 9 16 in 70 i Different _ _ diameter joint Drainhose t D 1 3 16 in Fig 3 _Do not make drain _as shown below i At least 1 31 32 in drain water Air end _ g5Op mm Water Water Water _ leakage leakage Waving...

Page 7: ... _ opper prpe Fig 1 Good 90 I Nogood i Tilted Uneven Burred Fig 2 Burr Copper pipe are reamer Pipe cutter Fig 3 Flaringtool ____ _utchtype Wing nuttype Fig 4 Smooth all around Inside is shin ing without any scratches Even length _ alt around _ Fig 6 A Die _ j_ Copper prpe Flare nut Fig 5 4 1 PURGING PROCEDURES AND LEAK TEST t Remove service port cap of stop valve on the side of the outdoor unit ga...

Page 8: ...panel assembly 4 Remove the panel assembly Be sure to remove its bottom end first 1 Fig 1 4 Fig 2 installation procedure Fig 3 4 t Point the horizontal vane slightly downward 2 Attach the bottom of the panel assembly under the horizontal vane 3 Fit in the top of the panel assembly 4 Fit in the bottom of the panel assembly and tighten it using screws 5 Push the section of the front panel marked by ...