OB274-24
(4) The initial set temperature is decided by the initial room temperature.
w
1
COOL mode of
“I FEEL CONTROL”
DRY mode of
“I FEEL CONTROL”
Mode
Initial room temperature
79
-
F or more
77
-
F to 79
-
F
55
-
F to 77
-
F
Initial room temperature
minus 4
-
F
Initial room temperature
minus 4
-
F
Initial set temperature
75
-
F
Operation time chart
Example
Previous operation
COOL mode of
“I FEEL CONTROL”
or COOL mode
●
Once the mode is fixed, the mode will not change by room temperature afterwards.
●
Under the ON-TIMER operation, the mode is determined according to the room temperature at set time the operation
starts.
●
When the system is stopped with the OPERATE/STOP(ON/OFF) button on the remote controller, and restarted within 2
hours in “I FEEL CONTROL” mode, the system operates in previous mode automatically regardless of the room temper-
ature.
Operation time chart
Example
Previous operation
COOL mode of
“I FEEL CONTROL”
or COOL mode
●
When the system is restarted after 2 hours or more, the operation mode is determined by the room temperature at start-
up of the operation.
Restart
COOL mode of
“I FEEL CONTROL”
Restart
COOL or DRY mode of
“I FEEL CONTROL” that
determined by room
temperature at start-up of
the operation.
Initial room temperature
mode
more than 77
-
F
55
-
F to 77
-
F
COOL mode of
“I FEEL CONTROL”
DRY mode of
“I FEEL CONTROL”
9-1. “I FEEL CONTROL” OPERATION
(1) Press OPERATE/STOP(ON/OFF) button on the remote con-
troller. OPERATION INDICATOR lamp of the indoor unit will
turn on with a beep tone.
(2) Press OPERATION SELECT button to set “I FEEL CONTROL”
Then a beep tone is heard.
(3) The operation mode is determined by the room temperature at
start-up of the operation.
w
1 When the system is restarted with the remote controller, the system operates with the previous set temperature regard-
less of the room temperature at restart.
The set temperature is calculated by the previous set temperature.