1 SERVO PARAMETER DETAILS
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
*1 "mm/s" is used instead of "r/min" for linear servo motors.
*2 Available on servo amplifiers with firmware version A5 or later.
*3 Available on servo amplifiers with firmware version B0 or later.
*4 Available on servo amplifiers with firmware version B8 or later.
[Pr. PF87.4-6_Drive recorder - Analog channel 2 selection]
Select the analog channel 2 of the drive recorder.
The servo parameter is disabled in the following conditions.
• [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode)
Refer to the following for values that can be assigned.
Page 141 [Pr. PF87.0-2_Drive recorder - Analog channel 1 selection]
[Pr. PF88_Drive recorder - Analog channel setting 2 (DRAC2)]
[Pr. PF88.0-2_Drive recorder - Analog channel 3 selection]
Select the analog channel 3 of the drive recorder.
The servo parameter is disabled in the following conditions.
• [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode)
Refer to the following for values that can be assigned.
Page 141 [Pr. PF87.0-2_Drive recorder - Analog channel 1 selection]
201
Servo motor speed +
0.1 r/min
32-bit data
202
Command pulse fre
kpulse/s
203
Command pulse frequency (speed unit) +
0.1 r/min
204
Droop pulses (1 pulse unit) +
pulse
205
Speed c
0.1 r/min
206
Position within one-revo
pulse
207
Load-side encoder information 1 +
pulse
208
Load-side encoder information 2+
rev
209
Load-side droop
pulse
20B
Feedback po
pulse
20C
Excessive error alarm
pulse
20D
Current position (positioning unit) +
pos units
20E
Command position (positioning unit) +
pos units
Command remaining distance (positioning unit) +
pos units
218
Droop pulses (100 pulse unit) +
100 pulse
219
Load-side encoder droop pulses (100 pulses unit) +
100 pulse
21A
Excessive error alarm margin (100 pulses unit) +
100 pulse
21B
Droop pulses (model position deviation) +
pulse
220
Speed command 2+
0.1 r/min
23C
Droop pulses (command unit) +
pulse
Initial value
Setting range
Ver.
002h
Refer to the text
A0
Initial value
Setting range
Setting method
Ver.
02040003h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
003h
Refer to the text
A0
Setting value
Data type
Unit
*1
Category