1 SERVO PARAMETER DETAILS
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
135
1
[Pr. PF81_Drive recorder - Sampling operation selection (DRMS)]
[Pr. PF81.0_Drive recorder - Sampling start selection]
Set this servo parameter to start drive recorder sampling.
When [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode), the setting value of the
servo parameter is disabled.
When this servo parameter is set to "1" or "2", if the settings of [Pr. PF80.2-3 Drive recorder - Sampling cycle selection] and
[Pr. PF82 Drive recorder - Trigger operation selection] to [Pr. PF94 Drive recorder - Digital channel setting 4] are changed, the
changed settings are not applied to the drive recorder. To apply the settings, cycle the power, reset the software, or set this
servo parameter to "0" (stop sampling), then set "1" or "2" again.
The storage area of the servo amplifier has a limit for the number of writings. If the trigger conditions that have been set in [Pr.
PF82] are frequently met, do not continue using this servo parameter when it is set to "2" (continuous sampling).
0: Stop sampling
1: Start a single sampling
2: Start a consecutive sampling
When "1" (start a single sampling) is set, if the trigger conditions are fulfilled after sampling starts, the drive recorder will
operate to save data once. After the data has been saved, this servo parameter will be "0" automatically.
When "2" (start a consecutive sampling) is set, if the trigger conditions are fulfilled after sampling starts, the drive recorder will
operate to save data. After that, sampling will start again.
Initial value
Setting range
Setting method
Ver.
00000000h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
A0